NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Inspecting/Cleaning Burner, Logs

and Controls

Qualified Service Technician

Inspect valve and ensure it is properly operating. Check piping

for leaks. Vacuum the control compartment, fireplace logs and

burner area.

Check Flame Patterns and Flame

Height

Qualified Service Technician

Refer to Figure 11 on Page 16 and verify the flame pattern

and height displayed by the appliance conforms to the picture.

Flames must not impinge on the logs. Ensure flames are steady

(not lifting or floating).

Inspecting/Cleaning Pilot and Burner

Qualified Service Technician

Refer to Figures 13 and 14 on Page 17. Remove any surface

build-up on pilot and burner assembly. Wipe the pilot nozzles,

igniter/flame rod and hood. Ensure the pilot flame engulfs the

flame sensor as shown.

Checking Vent System

Qualified Service Technician

Inspect the vent system at the top and at the base (within the

firebox) for signs of blockage or obstruction. Look for any signs

of dislocation or deterioration of the vent components. Note:

Excessive condensation can cause corrosion of caps, pipe &

fittings (excessive condensation can be caused by long lateral

runs, too many elbows and/or exterior portions of the system

being exposed to cold weather). Also inspect wall straps or

plumbers's tape to ensure it is secure and in place.

Appliance Checkout

Qualified Service Technician

Perform the appropriate appliance checkout procedure detailed

in this manual.

Replacing Glowing Ember (rockwool)

Materials

Homeowner/Qualified Service

Technician

Remove old ember materials (rockwool) and vacuum the ember

placement area. Place new embers as described in this document.

Periodically (After the Burning Season)

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Cleaning Firebox Interior

Homeowner

Carefully remove logs, glowing embers (rockwool), volcanic

stone and vermiculite. Vacuum out interior of the firebox. Clean

firebox walls and log grate. Replace logs, glowing embers and

vermiculite as detailed in this manual.

Check Flame Patterns and Flame

Height

Homeowner

Refer to Figure 11 on Page 16 and verify the flame pattern

and height displayed by the appliance conforms to the picture.

Flames must not impinge on the logs.

Checking Vent System

Homeowner

Inspect the vent system at the top and at the base (within the

firebox) for signs of blockage or obstruction. Look for any signs

of dislocation of the vent components.

Cleaning Front Glass Enclosure Panel

Homeowner

Clean as necessary following the directions provided in this

manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS

WHILE HOT.

Annually (Before the onset of the Burning Season)

MAINTENANCE SCHEDULE