LG SHADOWDANCE LSVFSD-LP User Manual
Page 7
 
Note: Diagrams aND illustratioNs are Not to scale.
7
Figure 3
Step 2. Ceiling Clearance: the ceiling must be at least 4" from the top
of the appliance opening (Figure 2).
Step 3. Noncombustible materials (minimum requirements): to install
the appliance without wood mantels, shelves or other combustible projec-
tions directly above the opening of the fireplace (firebox) refer to Figure
3 and Table 1. Note that at least 8" of noncombustible material must be
installed above the appliances described in this manual.
Noncombustible materials, such as slate and marble, must be at least
1/" thick.
Figure 4
16"
Min.
42"
Min.
Figure 2 - Clearances
Noncombustible
Material
8" or More of
Noncombustible
Material
Appliance in
Fireplace or
Firebox
Appliance in
Fireplace or
Firebox
Adjustable
Canopy
A
Step 4. Wood mantel, shelf or combustible projection requirements:
to install a wood mantel, shelf or other combustible projection directly
above the fireplace (firebox), refer to Table 2 and to Figures 5 and 6 for
installation profiles.
if your mantel profile is unsafe, you may either:
• raise the mantel to an acceptable height, or
• remove the mantel.
Example: The bottom of the mantel may project from the wall a maximum
of 2-1/2" at a minimum of 28" above the opening. The top shelf of the
mantel may project a maximum of 6" at a minimum of 34-1/2" above
the opening.
Noncombustible
Material
12"
28"
34-1/2"
38-5/8"
42"
10"
2-1/2"
6"
8"
Ceiling
Noncombustible Material Requirements with No Mantel Installed
(A) Noncombustible 
Material Measurement
Requirements for Safe Installation
1" or more
adjustable canopy not required.
8" minimum to 1"
install adjustable canopy.
less than 8"
extend noncombustible material to at least 8" and 
install adjustable canopy (Figure 4).
or
extend noncombustible material to a height of at 
least 1".
Table 1
Noncombustible Material Heights and Mantel Location
(A) Noncombustible 
Material Measurement
Requirements for Safe Installation with Wood 
Mantel, Shelf or Other Combustible Projection
1" or more
adjustable canopy not required. observe profiles 
shown in Figure 5.
8" minimum to 1"
install adjustable canopy and observe profiles shown 
in Figure 4.
or
extend heat resistant material to at least 1" and 
observe profiles shown in Figure 3 and 5.
Table 2
Figure 5