Note: Diagrams aND illustratioNs are Not to scale.

any outside air ducts and/or ash dumps in the fireplace shall be perma-

nently closed at time of appliance installation.
a qualified gas appliance installer must install this dual-listed appli-

ance.
Check gas type: The gas supply must be the same as stated on the

appliance’s rating plate. If the gas supply is different, DO NOT INSTALL

the appliance. Contact your dealer for the correct model.
Step 1. Unpack Appliance
- remove appliance from carton. cut tie-wires

holding ember bed rear log to the base. unwrap foam packaging from

ember bed rear log.
Step 2. Place Ember Bed Rear Log – Place the ember bed rear log with

ember chunks facing the front of the appliance such that the middle grate

bar aligns with the notch in the top of the ember piece. Push the ember

bed rear log toward the front of the unit until it touches the lip on the

base and cannot go any further.
Step 3. Placement of Appliance – center the appliance in the fireplace

or firebox. make certain the grate front feet sit inside the front edge of

the fireplace or firebox, and that there is adequate clearance around the

appliance for access and operation.
Step 4. Connecting Gas Line – a qualified gas appliance installer must

connect the dual-listed gas appliance to the gas supply.
Step 5. Place Logs – see log placement on Page 10.
consult all local codes.
route gas line using techniques and materials prescribed by local

and/or national codes. only use 1/" or greater pipe size to allow full gas

volume to the gas fireplace. undue pressure loss will occur if the pipe

is too small.
an aNsi approved manual shut-off valve and union must be installed upstream

of the appliance within the fireplace cavity when rigid pipe is used.
IMPORTANT: HOLD APPLIANCE REGULATOR WITH A WRENCH TO

PREVENT MOVEMENT WHEN CONNECTING TO INLET PIPING
an external regulator must be used on all propane (l.P.g.) appliances,

in addition to the regulator fitted to the appliance, to reduce the supply

tank pressure to 1" W.c. (maximum).

Example: The bottom of the mantel may project from the wall a maxi-

mum of 2-1/2" at a minimum of 8" above the opening. The top shelf of

the mantel may project a maximum of 6" at a minimum of 14-1/2" above

the opening.

the appliance base may be lower than 5" above the combustible flooring

materials if the combustible flooring materials are more than 14" from the

fireplace or firebox opening (Figure 8).

Step 5. Floor clearance: if combustible flooring materials, such as carpet-

ing or asphalt tile, are to be located within 14" of the fireplace or firebox

opening, the appliance base must be at least 5" above the combustible

flooring material (Figure 7).

Noncombustible

Material

14-1/2"

18-5/8”

22-1/2"

26"

10"

2-1/2"

6"

8"

12"

8"

Min.

Hood (Canopy)

Combustible Flooring

Material

5" Min.

Combustible

Flooring

Material

Can be less

than 5"

14" Min.

Figure 8

Figure 7

Figure 6

INSTALLATION

WARNINGS

Do not use a blower insert, heat exchanger

insert or other accessory not approved

for use with this heater.

Installed decorative glass door enclosures must be

fully opened when operating this dual-listed gas

appliance.

Special care is required if you are installing the unit

into a sunken fireplace. You must raise the fireplace

floor to allow access to gas log controls. This will

ensure adequate air flow and guard against soot-

ing. Raise the fireplace floor using noncombustible

materials.

WARNING

Connecting directly to an unregulated propane tank may

cause an explosion.