NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

10

MILLIVOLT WIRING DIAGRAM

VENTED/UNVENTED GAS LOG APPLIANCE TECHNICAL CHART FOR MILLIVOLT LOG SET

BTU/HR

Regulator

Gas Inlet

Valve

Model No.

Input

Gas Type

Ignition

Pres. Setting

Pressure*

Operation

Orifice Size

* For the purpose of input adjustment.

SHGL - 18VN-R

36,000

Natural

Piezo

1.6 – 3.5" w.c.

Max. 10.5" w.c.

Millivolt

0.113

24,000

Min. 5.0" w.c.

SHGL - 18VP-R

36,000

Propane/LPG

Piezo

6.3 – 10.0" w.c.

Max. 13" w.c.

Millivolt

0.069

24,000

Min. 11" w.c.

SHGL - 24VN-R

39,000

Natural

Piezo

1.6 – 3.5" w.c.

Max. 10.5" w.c.

Millivolt

0.119

28,000

Min. 5.0" w.c.

SHGL - 24VP-R

39,000

Propane/LPG

Piezo

6.3 – 10.0" w.c.

Max. 13" w.c.

Millivolt

0.072

29,000

Min. 11" w.c.

PILOT (O.D.S.)

ASSEMBY

THERMOPILE

WHITE

WHITE

RED

BLACK

OFF

ON

MILLIVOLT VALVE

ON/OFF SWITCH

AND PILOT IGNITOR

OPTIONAL

REMOTE CONTROL

(MILLIVOLT)

IGNITION
WIRE

Advertising
This manual is related to the following products: