NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

5

Example: The bottom of the mantel may project
from the wall a maximum of 2

¹ ₂" at a minimum

of 8" above the opening. The top shelf of the
mantel may project a maximum of 6" at a
minimum of 14

¹ ₂" above the opening.

Noncombustible Material Requirements with No Mantel Installed

(A) Noncombustible Material Measurement

Requirements for Safe Installation

12" or more

Adjustable canopy not required.

8" minimum to 12"

Install adjustable canopy.

Less than 8"

Extend noncombustible material to at least
8" and install adjustable canopy (

Figure 3 ).

or
Extend noncombustible material to a height
of at least 12".

Table 2

Noncombustible Material Heights and Mantel Location

Requirements for Safe Installation

with Wood Mantel, Shelf or

Noncombustible Material Measurement

Other Combustible Projection

12" or more

Adjustable canopy not required. Observe pro-
files shown in

Figure 4.

8" minimum to 12"

Install adjustable canopy and observe pro-
files shown in

Figure 5.

or

Extend heat resistant material to at least 12"
and observe profiles shown in

Figure 4.

Table 3

Step 4. Wood mantel, shelf or combustible
projection requirements:
To install a wood
mantel, shelf or other combustible projection
directly above the fireplace (firebox), refer to
Table 3 and to Figures 4 and 5 for installation
profiles.

If your mantel profile is unsafe, you may either:

Raise the mantel to an acceptable height, or

Remove the mantel.

Example: The bottom of the mantel may project
from the wall a maximum of 2

¹ ₂" at a minimum

of 28" above the opening. The top shelf of the
mantel may project a maximum of 6" at a
minimum of 34

¹ ₂" above the opening.

Figure 6

The appliance base may be lower than 5" above
the combustible flooring materials if the com-
bustible flooring materials are more than 14"
from the fireplace or firebox opening (

Figure 7 ).

Figure 7

Figure 5

Step 5. Floor clearance: If combustible floor-
ing materials, such as carpeting or asphalt tile,
are to be located within 14" of the fireplace or
firebox opening, the appliance base must be at
least 5" above the combustible flooring material
(

Figure 6 ).

Noncombustible
Material

12"

28"

34

¹⁄₂"

38

⁵⁄₈"

42"

10"

2

¹⁄₂"

6"

8"

Ceiling

Figure 4

Noncombustible
Material

14

¹⁄₂"

18

⁵⁄₈"

22

¹⁄₂"

26"

10"

2

¹⁄₂"

6"

8"

12"

8"

Min.

Hood (Canopy)

Combustible Flooring
Material

5" Min.

Combustible
Flooring
Material

Can be less

than 5"

14" Min.