Lennox Hearth SHGL-18MP-R User Manual

Page 7

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

7

Figure 10

WARNING: FAILURE TO POSITION THE
PARTS IN ACCORDANCE WITH FIGURE
10 OR FAILURE TO USE ONLY PARTS
SPECIFICALLY APPROVED WITH THIS AP-
PLIANCE MAY RESULT IN PROPERTY
DAMAGE OR PERSONAL INJURY.

WARNING: DO NOT PLACE ANY LAVA
ROCK ON LOGS OR BURNERS. THIS MAY
CAUSE SOOTING. ONLY PLACE LAVA
ROCK ON FLOOR OF FIREPLACE.

Step 4. Placing the Logs

WARNING: DO NOT ADD EXTRA LOGS OR
ORNAMENTS SUCH AS PINE CONES, VER-
MICULITE OR ROCK WOOL. USING THESE
ADDED ITEMS CAN CAUSE SOOTING.

Periodically check the positioning of all logs.

Flame Appearance

REFER TO THE OPERATING INSTRUCTIONS
LOCATED AT THE BACK OF THIS MANUAL
BEFORE LIGHTING THE APPLIANCE TO OB-
SERVE THE FLAMES.

Flames from the pilot burner should be visu-
ally checked as soon as the appliance is in-
stalled. In addition a periodic visual check of
the flames should be made. The pilot flame
should always be present when the appliance
is in operation (

Figure 11 ).

The pressure regulator on manual models is
preset and locked to avoid tampering. If the
pressure is not as specified in the Technical
Details Chart on page 10, replace the regulator
with P/N 110353 for natural gas and P/N
120341 for propane (L.P.G.) heaters.

Replace the test point plug after pressure
measurement ensuring no gas leaks.

Figure 9

The heater has a unitized base, a front log and
a top twig. It is important to follow the
instructions to place the logs properly over the
burner assembly.

1. Place the front log as shown in

Figure 9 (A).

Position the front log so it fits between the
burner and the front grate bars, resting com-
pletely on the grate base.

2. Place the unitized log set over the burner
assembly as shown in

Figure 9 (B). Be sure

the unitized log set is against the sides of the
burner and is resting down completely over
the grate.

3. When placing the unitized log set over
the burner assembly and resting it against
the sides of the burner, make sure the bot-
tom of the log set sits down completely over
the grate as shown in

Figure 9 (C).

4. Place and lock the top twig over the twig
pins as shown in

Figure 9 (D).

5. For an optimum flame, be sure that the
unitized log set rests against the burner at the
two places shown in

Figure 9 (E).

WARNING: NO ADJUSTMENTS ARE TO
BE MADE TO THE ODS PILOT SYSTEM.
TAMPERING WITH THIS SYSTEM CAN
BE EXTREMELY HAZARDOUS.

Manual Log Set

Millivolt Log Set

Grate Base

A

Grate Bar

Front Log

Unitized Log Set

B

C

Twig Pins

Unitized Log Set Must
Lay Flat On Grate Base

D

Unitized Log Set Must Be Placed Against Burner Bracket
At These Two Places

Top Twig

E

Advertising