9

POWER, BATTERY, & GROUND WIRING

Power Wiring

NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS

COMPLETE.

1. Route two wires between the RE-1 and the power transformer.

• For power wire runs up to 100 feet, use 18 AWG, THHN 600-volt

insulated wire.

• For power wire runs up to 200 feet, use 16 AWG, THHN 600-volt

insulated wire.

2. Connect the wires to the transformer. Connect the other end of the

wires to the two RE-1 TRANSFORMER terminals.

Backup Battery

Use of battery backup is optional. It will allow the RE-1 to operate for
short periods of time without AC power. Two 12-volt backup batteries
in series are recommended to obtain the proper working voltage for
the RE-1. A single 12-volt battery can be used, although the call
waiting beeps and the ring voltage will be lower than normal when
fi ve telephones are connected. The door or gate access device
must use some type of battery backup for the entire system to be
functional.
Backup batteries will not fi t into the RE-1 housing. Protect the backup
batteries inside a rain-tight NEMA enclosure suitable for the installation.

NOTE: Backup batteries are not required to maintain the RE-1 clock/

calendar and programming memory during power outages.

1. Route two wires between the RE-1 and the backup batteries.
2. Connect two 1.2 Amp/hour (minimum), 12-volt, gel cell batteries in

series (Battery #1 negative to Battery #2 positive).

3. Connect the Battery #1 positive to the RE-1 BATTERY POSITIVE

terminal.

4. Connect the Battery #2 negative to the RE-1 BATTERY NEGATIVE

terminal.

NOTE: The RE-1 does not supply battery charging current. An

external battery charger will be required to maintain the batteries.

Earth Ground

For the best ground, use size 12 gauge solid wire or larger to
connect the to an 8-foot copper ground rod. Locate the ground rod
next to the Power and Telephone company rods and bond the rods
together with a new clamp. Do not disturb the clamps installed by
the Power or Telephone Company. Alternately, connect to a cold
water pipe for the earth ground.

1. Connect the RE-1 EARTH terminal to the earth ground wire.
2. Connect the Telephone Bypass Module EARTH GROUND terminal to

the earth ground wire.

OPTIONAL REMOTE KEYPAD

The optional Model AM-KP remote keypad can be used with the
RE-1 entry system. A typical application for the remote keypad
would be to control a second door or gate. Entry codes are the only
method of access allowed at a remote keypad. The default system
setting will cause the remote keypad to activate Relay #2.

1. Mount the AM-KP keypad onto a pedestal or to a wall.
2. Route 6-conductor cable from the RE-1 to the AM-KP.

• For wire runs up to 300 feet use 24 AWG Belden Type 9931 or

equivalent.

• For wire runs up to 600 feet use 20 AWG Weico Type 9405 or

equivalent.

3. Set

the

DEVICE ADDRESS rotary switch in the AM-KP to match the

remote keypad address in the RE-1 (default = 3).

4. Connect the 6-conductor cable as shown in Figure 17.
5. Secure and lock the AM-KP to its mounting plate.

SET SWITCH
TO NUMBER 3

Figure 16. Setting the Keypad Device Address

RE -1

TRANSFORMER

TELCO

OPEN #1

KEYPAD GND

KEYPAD DAT 1

KEYPAD DAT 0

KEYPAD PWR

TRANSFORMER

TRANSFORMER

BATTERY NEGATIVE

BATTERY POSITIVE

SENSE #1

COMMON

KEYPAD CLK

KEYPAD DVAL

OPEN #2

RE-1

TERMINALS

SENSE #2

GROUND

STAKE

RI

NG

TIP

RI

NG

TIP

EARTH

HOUSE

NOTE: BACKUP BATTERIES
WILL REQUIRE AN
EXTERNAL CHARGER

TIP

RING

TIP

RING

TIP

RING

TIP

RING

TELCO

RE-1

TELCO

RE-1

HOUSE

HOUSE

TELEPHONE

BYPASS

MODULE

EARTH

GROUND

12 VOLT

1.2 AMP/HR

BATTERY

12 VOLT

1.2 AMP/HR

BATTERY

NOTE: TWO 12-VOLT BATTERIES ARE
RECOMMENDED, ALTHOUGH ONE
12-VOLT BATTERY CAN BE USED

Figure 15. Power, Backup Battery & Ground Wiring

OPEN #1

KEYPAD GND

KEYPAD DAT 1

KEYPAD DAT 0

KEYPAD PWR

TRANSFORMER

TRANSFORMER

BATTERY NEGATIVE

BATTERY POSITIVE

SENSE #1

COMMON

KEYPAD CLK

KEYPAD DVAL

OPEN #2

RE-1

TERMINALS

SENSE #2

PWR

GND

DAT1

DAT0

DVAL

CLK

AM-KP

REMOTE

KEYPAD

USE BELDEN 9931 (24 AWG) CABLE FOR RUNS UP TO 300 FEET

USE WEICO 9405 (20 AWG) CABLE FOR RUNS UP TO 500 FEET

Figure 17. Remote Keypad Wiring