Optional keyswitch – Linear RE-1 User Manual

Page 12

Advertising
background image

10

OPTIONAL KEYSWITCH

A keyswitch can be installed in the RE-1 Entry System to provide
keyed access. The RE-1 case is designed to accept the following
keyswitch:

KNOX COMPANY MODEL 3501

KNOX COMPANY

800-552-5669

www.knoxbox.com

Keyswitch Installation

1. Disconnect the wiring harness connector and remove the antenna

terminal block. Remove the four circuit board retaining screws and the
RE-1 circuit board (see Figure 18).

2. Remove the screw and washer that retain the keyswitch hole access

plate (see Figure 19).

3. Hold the lock cover and plastic spacer in place on the RE-1 case.

Secure the assembly with four screws, lock washers, and nuts. Slide
the keyswitch into the hole, oriented as shown (see Figure 20).
Secure the keyswitch with the large switch nut. Use bolt cutters to trim
the two screws closest to the case edge so they will clear the circuit
board (see Figure 21).

4. Plug the two keyswitch snap-on wire leads (supplied with the switch)

onto the keyswitch COM and N.O. pins (see Figure 21).

5. Replace the RE-1 circuit board. Secure the board with the four

screws. Reconnect the antenna terminal block and wiring harness
connector.

6. Connect one keyswitch wire to the RE-1 OPEN #1 terminal. Connect

the other keyswitch wire to the RE-1 COMMON terminal.

DISCONNECT THESE
TWO CONNECTORS

REMOVE THESE
4 SCREWS

REMOVE
CIRCUIT
BOARD

Figure 18. Removing the RE-1 Circuit Board

REMOVE THE
SCREW AND
WASHER

REMOVE THE
COVER PLATE

INSTALL COVER PLATE
AND SPACER WITH FOUR
SCREWS, LOCKNUTS, & NUTS

SPACER

COVER
PLATE
ASSEMBLY

INSERT KEYSWITCH
INTO HOLE WITH
KEYSLOT ORIENTED
AS SHOWN

Figure 20. Installing the Keyswitch

COM

N.O.

SWITCH
PINS

CONNECT SWITCH WIRES
TO COM AND N.O. PINS

SWITCH SECURED
WITH LARGE NUT

BOLTS CUT SHORT
TO CLEAR CIRCUIT
BOARD

Figure 21. Keyswitch Wire Connections

ACCESS

KEYSWITCH

OPEN #1

KEYPAD GND

KEYPAD DAT 1

KEYPAD DAT 0

KEYPAD PWR

TRANSFORMER

TRANSFORMER

BATTERY NEGATIVE

BATTERY POSITIVE

SENSE #1

COMMON

KEYPAD CLK

KEYPAD DVAL

OPEN #2

RE-1

TERMINALS

SENSE #2

NOTE: THE KEYSWITCH CAN BE WIRED TO
THE OPEN #2 TERMINAL TO CONTROL
A SECOND GATE OR DOOR

Figure 22. Keyswitch Wiring

Figure 19. Removing the Keyswitch Hole Access Plate