Call Forwarding Feature

Default: OFF

The call forwarding feature will allow a visitor to contact the resident at
the programmed telephone number instead of through the local telephone
line. The feature can be set to be active during a selected Time Zone or
at all times. The telephone number programmed can contain an extension
number and an optional time delay before dialing the extension.

Press:

Forwarding

Time Zone

Telephone Number

Extension

Delay

Forwarding: 0 = Call forwarding feature OFF

1 = Call forwarding feature ON at all times

2 = Call forwarding feature ON (scheduled by Time Zone)

3 = Forward the call if there was no resident answer

Time Zone = 1-7 (Call forwarding feature active during this Time Zone)
Telephone Number = Up to 11-digit telephone number
Extension = Up to 4-digit telephone extension number
Delay = 1-25 seconds (delay between telephone number and extension)

Example, call forwarding with only a phone number:

Press:

or

Telephone Number

A special feature is implemented for “Ring Down” PBX systems. If no
telephone number is programmed and call forwarding is enabled, the unit
will connect immediately without dialing.

Example, call forwarding with extension and no time zone:

Press:

or

Telephone Number

Extension

Delay

Example, call forwarding scheduled by time zone:

Press:

Time Zone

Telephone Number

Extension

Delay

NOTE: Time zone is only used with forwarding = 2

Example, call forwarding off:

Press:

Alternate Resident Telephone Numbers

Default: All Disabled

For installations where multiple residences exist behind shared controlled
access, the RE-1 can dial three alternate telephone numbers. The visitor can
call an alternate number by entering “1#”, “2#”, or “3#” on the main keypad.

Press:

Location

Enable

Telephone Number

Extension

Delay

Location: 1 = “1#” location; 2 = “2#” location; 3 = “3#” location
Enable: 0 = Disable; 1 = Unconditionally enable
Telephone Number: Up to 11-digit telephone number
Extension: Up to 4-digit telephone extension number
Delay: 1-25 seconds (delay between telephone number and extension)

Resident Response Telephone Keys

Defaults:

Key A “1” = Activates Relay #1

Key B “2” = Activates Relay #2

Key C “9” = Disconnect Visitor’s Call

Key D “6” = Switch To/From Call Waiting

The resident response keys are the telephone keys that the resident uses to
grant access and control calls from a visitor. The keys for the four functions
can be customized. Enter all four keys each time this programming PPN is
used.

Press:

Keys ABCD

Keys ABCD: Enter 4 digits for the response keys A, B, C, & D

Key A = Activates Relay #1

Key B = Activates Relay #2

Key C = Disconnects the Visitor’s Call

Key D = Switches to and from a call holding on call waiting

Resident Programming and Command Prefi xes

Defaults:

Programming = “###”

Command = “##”

The resident command prefi x is entered on a local telephone prior to
entering a command number to control one of the relays or open voice
communications with the RE-1. The resident programming prefi x is entered
on a local telephone or the main keypad prior to programming the RE-1.

Press:

Programming

Command

Programming: 0 = “###”; 1 = “***”; 2 = “*#*”; 3 = “#*#”

Command: 0 = “##”; 1 = “**”; 2 = “*#”; 3 = “#*

ADVANCED SYSTEM PROGRAMMING

Reset System Defaults

The system can be reset back to the factory defaults with this programming
PPN. EXECUTING THIS PPN WILL NOT ERASE ANY ENTRY CODES OR
TRANSMITTERS THAT HAVE BEEN PROGRAMMED.

Press:

Relay #1 On Time

Default 2: Seconds

Changes the length of time Relay #1 activates when triggered.

Press:

Time

Seconds = Output time in seconds 0-60

Relay #2 On Time

Default: 2 Seconds

Changes the length of time Relay #2 activates when triggered.

Press:

Time

Seconds = Output time in seconds 0-60

Main & Remote Keypad Relay and Time Zone

Default: Main Keypad = Set by Entry Code, No Time Zone

Remote Keypad = Relay #2, No Time Zone

Sets the relay and time zone that the main and remote keypad will use.

Press:

Keypad

Relay

Time Zone

Keypad: 1 = Main Keypad

2 = Remote Keypad

(Also see PPN #28)

Relay: 1 = Relay #1

2 = Relay #2

3 = Set by entry code

Time Zone: 0 = no time zone

1-7 to restrict access per time zone 1-7

NOTE: To have an entry code select which relay activates, the relay

option should be set to “3”.