COMMUNICATIONS

The PowerSure™ Personal UPS contains a standard DB-9 receptacle located on
the rear of the UPS unit. Several signals are provided on this port and are
assigned as follows:

PIN

ASSIGNMENT DESCRIPTION

1

Low Battery (open collector)

2 No

connection

3 No

connection

4

On Battery Mode Shutdown (5-12 DC)

5

On Battery Mode Shutdown Return

6

Utility Fail / Normally On (open collector)

7

Low Battery (open emitter)

8

Utility Fail (common) (pins 6 & 9)

9

Utility Fail / Normally Off (open collector)

*Maximum voltage and current on pins 1, 6, 7, 8, 9 is 60V DC; 5.0 mA.

Collector to Emitter*

Open Collector

(+)

(-)

Open Emitter

Pin Assignment