Lennox Hearth Ladera-BK User Manual

Page 16

Advertising
background image

Roof Down Slope Hole Size

SLOPE

ASHT+ / HT6103+

S-2100+ / HT6000+

AC

Roof Pitch

6”

6”

6”

0 *

12-3/8” (314 mm)

14-1/8” (359 mm)

15” (380 mm)

2/12

12-9/16” (319 mm)

14-3/8” (365 mm)

15 3/8” (390 mm)

4/12

13” (330 mm)

14-7/8” (378 mm)

16 1/8” (410 mm)

6/12

13-7/8” (352 mm)

15-3/4” (400 mm)

16 7/8” (430 mm)

8/12

14-7/8” (378 mm)

17” (432 mm)

18 1/4” (465 mm)

10/12

16-1/8” (410 mm)

18-3/8” (467 mm)

19 5/8” (500 mm)

12/12

17-1/2” (445 mm)

20” (508 mm)

21 3/8” (545 mm)

Table 3

* Cross Slope Hole Size

Figure 26

Figure 27

Figure 31

Minimum Chimney Height Using Elbows

Fireplace Model

Ladera™

Chimney Model

ASHT+ / S2100+ / HT6103+ / HT6000+ / AC

Vertical installation

12 feet (3.66 m)

Two (2) elbows

15 feet (4.57 m)

Four (4) elbows

17 feet (5.18 m)

Table 4

After reaching the location requiring the

elbow, proceed as follows:

ASHT+ / HT6103+ / S-2100+ / HT6000+

Chimneys

1. Install the first elbow; turn it in the required

direction. Fasten it to the chimney with

the three (3) 1/2” (12 mm) metal screws

provided with the elbow.

2. Install the necessary chimney lengths to

achieve the required offset. Lock the chimney

lengths together: it is recommended to use

three (3) 1/2” (12 mm) screws. If the offset

length is made of two (2) chimney lengths or

more, use an offset or roof support halfway

up the offset. If penetrating a wall, install

a wall radiation shield (see Figures 30 and

31).

3. Use another elbow to turn the chimney

vertically. Secure the elbow, using three

(3) 1/2” (12 mm) screws (provided with the

elbow).

4. Use a plumb-bob to line up the center of

the hole. Cut a hole for the chimney in the

ceiling/floor. Frame this hole as described

previously (refer to section Chimney Instal-

lation Instructions).

5. From below, install a firestop (See Figure

24a).

6. A support (ST or SO) must be used on the

first 15’ section (5 m).

7. Continue with the regular installation.

AC Chimney

1. Install the first elbow. Turn it in the required

direction. To lock it in place, turn 1/8 of a

turn. Fasten the straps attached to the elbow

to the surrounding frame, using nails or

drywall screws (see Figure 29).

2. Install the necessary chimney lengths to

achieve the required offset. Lock the chimney

lengths together. If penetrating a wall, use

a wall radiation shield.

3. Use another elbow to turn the chimney

vertically. Lock it to the chimney. Fasten

the straps attached to the elbow to the

surrounding framing using nails or drywall

screws.

4. Use a plumb-bob to line up the center of the

hole. Cut a hole for the chimney in the ceiling.

Frame this hole as described previously.

5. From below, install a firestop (see Figure

24b).

6. Continue with the regular installation.

Note: When using AC chimney, an AC6SB

starter section must be used before installing

an elbow. When an offset is needed imme-

diately off the top of the fireplace, an elbow

starter section (AC6SB30) is available.

AC

Air Cooled Chimney

Collar

Chimney

Flashing

OFFSET CHIMNEY INSTALLATION

After reaching the location requiring the elbow, proceed as follows. The minimum chimney height

when using elbows is:

Spacer (built

into flashing)

Note: Must return to vertical before penetrating ceiling or floor.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

16

Advertising