ANGLED WALL RADIATION SHIELD

(RSM+ and RSMI30)

When traversing a combustible wall with the chimney at a 30º or 45º

angle, an angled firestop or wall radiation shield must be installed. Only

one is required.

Note: 45º angle for Canada only (

RSMI45)

In cold climate locations (climates where temperatures will fall below 32°

F / 0° C), we recommend that you use the insulated wall radiation shield

since it will maintain the home’s thermal barrier.

RSM+ and RSMI30

(RSMI45 - Canada Only)

Chimney Model

Angle

Hole Size

ASHT+ / HT6103+

(6” dia). Canada only

30º

283 mm x 781 mm (11-1/8” x 30-3/4”)

45º

283 mm x 518 mm (11-1/8” x 20-3/8”)

S-2100+ / HT6000+ /

AC (6” dia).

30º

327 mm x 881 mm (12-7/8” x 34-11/16”)

30º

380 mm x 972 mm (15” x 38-1/4”)

Table 5

Figure 31

Drywall

Insulated Wall

Insulated Wall

Radiation Shield

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.