4-WIRE CONNECTION WITH

A POWER SUPPLY CORD

• Only a 4-conductor power-supply cord kit rated

120/240 volts, 50 amperes and marked for use
with ranges with closed-loop connectors or
open-end spade lugs with upturned ends shall
be used. The middle (neutral) wire of the power
cord or 4-wire conduit has to be connected to
the middle post of the main terminal block.
The other two wires of the power cord or
conduit have to be connected to the outside
posts of the main terminal connection block.
The 4th ground wire must be connected to the
frame of the range with the ground screw.

- Failure to do so can result in electrical shock,

severe personal injury or death.

WARNING

Install the power cord as follows:

For power cord installations, Hook the strain relief over
the power cord hole (1

3

/

8

”) located below the rear of

lower oven. Insert the power cord through the strain
relief and tighten it. (Refer to Figure 7.)

DO NOT install the power cord without a strain relief.

1. Remove the lower 3 screws from the terminal block

and retain them. (Refer to Figure 9.)

2. Remove ground strap and discard as show in in

Figure 9.

3. Insert the ground screw into the power cord ground

wire terminal ring and secure it to the range frame.

4. Insert the 3 screws through each power cord terminal ring

and into the lower terminals of the terminal block. Make
sure that the center wire (white/neutral) is connected to
the center lower position of the terminal block.

5. Tighten 3 screws securely into the terminal block.

4-wire connection

Terminal

block

Conduit

connection plate

Ground screw

Remove ground

strap and discard

Ground

strap

Black White Red

FIgURE 9

3-WIRE CONNECTION: CONDUIT

Install the conduit as follows:

Remove the Conduit connection plate from the rear of
lower oven and rotate it as shown in Figure 5. The
conduit hole (1

1

/

8

") must be used.

First, prepare the conduit wires as shown in Figure 10.

3 wire

4 wire

Conduit

connection

plate

or

Ground

strap

FIgURE 10

Second, install conduit as shown in Figure 6.
For conduit installations, after purchasing a strain relief,
insert it in the conduit hole (1

1

/

8

”). Then install the

conduit through the body of strain relief and fasten the
strain relief with its ring. Reinstall the bracket.
For conduit connections :
If the wire in the conduit is copper it must be 8 or 10
AWG wiring.
If the wire in the conduit is aluminum it must be 6 or 8
AWG wiring.
1. Loosen the lower 3 screws from the terminal block.

Refer to Figure 11.)

2. Insert the bare wire (white/neutral) end through the

center terminal block opening. Do not remove ground
strap connections.

3. Insert the two side bare wire ends into the lower left

and the lower right terminal block opening. Tighten
the 3 screws securely into the terminal block.
(approximately 35 - 50 IN-LB)

4. Refer to page 11.

3-wire connection

Terminal

block

Wire ends

Conduit

connection plate

Black White

Red

FIgURE 11