Impinger I -–Adv Digital – Electric Service Manual - International

8

plug to be sure it is firmly in receptacle. Measure

incoming power, call power co. if required.

Fuse, 10 Amp

Check, replace if necessary.

Fuse holder

Check, replace if necessary.

Switch, oven power

Check for line voltage supplied to switch. If no voltage

is present, trace wiring back to fuse holder. Check

continuity between switch terminals. Replace switch as

needed.

Control transformer

Check for supply voltage to primary of control

transformer. If no voltage is present, trace wiring back to

oven power switch. If voltage is present, check for

24VAC at transformer secondary. If there is primary

voltage, but no secondary voltage, replace control

transformer.

Conveyor motor

Check for supply voltage to the conveyor motor at

terminal #8 to neutral. If no voltage is present, trace

wiring back to oven power switch. If voltage is present,

but the motor will not run, check the motor windings for

opens or shorts. If any of the above checks fail, replace

conveyor motor.

Capacitor, conveyor motor

Check for shorts or grounds. Replace capacitor as

needed.

WARNING: Capacitor has a stored charge, discharge

before testing.

Switch, conveyor reversing

Check continuity between switch terminals. Replace

switch as needed.

Oven control

If there is voltage supplied to the motor, and the motor

capacitor and reversing switch check good, replace the

oven control.

Conveyor motor runs,

but there is no speed

display

NOTE: Display will indicate

“BELT JAM”

Oven control

Check for output voltage from oven control to hall effect

sensor (sensor is located in the conveyor motor).

Measure voltage at the motor connector, red wire and

yellow wire. Voltage should be approx. 10VDC. If no

voltage is present, trace wiring back to oven control. If

there is no voltage output at the oven control, replace

oven control.

Conveyor motor

If there is voltage supplied to the hall effect sensor,

check for a frequency output from the hall effect sensor.

Measure frequency across the yellow and white wires in

the motor connector. Frequency reading should be

approx. 25-100 Hz. If these readings are not achieved,

replace conveyor motor. If the readings are achieved,

proceed.

Oven control

If the hall effect sensor readings are correct, but there is

no speed indicated on the display, replace the oven

control.

REMOVAL, INSTALLATION & ADJUSTMENTS

IMPINGER ADVANTAGE SERIES

CAUTION!

BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER

OVEN BE SURE TO DISCONNECT ELECTRICAL POWER AND GAS SUPPLY