NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Test gauge connections are provided on the

front of the millivolt gas control valve (identi-

fied IN for the inlet and OUT for the manifold

side). See Figures 1 & 2.

This appliance must not be connected to a

chimney or flue serving a separate solid-fuel

appliance.

Burn-in Period

During the first few burns of these appliances

there will be some odor due to the curing of the

high temperature paint and burning off of lubri-

cants used in the manufacturing process.

Depending on your use, the burn-in period may

take a few hours or a few days. Do not turn on

blower during Burn-In period.

IMPORTANT

Keep your house well ventilated

during the curing process. The

odor and haze emitted by the

curing process can be quite

noticeable and may set off a

smoke detector.

O N

OFF

PIL

OT

LO

H

I

Figure 1

GAS CONTROL

KNOB

CONVERTIBLE

HI/LO REGULATOR

(adjusts flame height

and heat output)

INLET

PRESSURE

TAP

PILOT

ADJUSTMENT

SCREW

WIRING

TERM-

INALS

OUTLET

PRESSURE

TAP

Model EBVI30

Honeywell Millivolt Gas Valve Controls

TP/TH

PIEZO

IGNITER

TH

TP

H I

LO

W

TPTH

TP

TH

PIL

OT

PI

LO

T

ON

it

OF

F

IN

OUT

Figure 2

MODEL EBVI5

SIT Millivolt Gas Valve Controls

GAS CONTROL

KNOB

INLET

PRESSURE

TAP

OUTLET

PRESSURE

TAP

CONVERTIBLE

HI/LO REGULATOR

(adjusts flame height

and heat output)

PIEZO

IGNITER

GAS CONTROLS

These millivolt appliances are fitted with a burner

Off/On Switch, located on the side surround

panel as shown in Figure 4 on Page 4. Once the

pilot is lit, and valve knob is in the ON position,

the Off/On switch will control the appliance

Off/On operation. To operate, toggle the switch

between its ON and OFF positions.

Variable Flame Height Adjustment

These millivolt appliances are equipped with

variable gas control valves. Flame height may

be adjusted through a range between fixed low

and high settings by rotating the HI/LO knob on

the valve (see Figures 1 & 2) while the appliance

is in operation.

Lighting Millivolt Appliances

To light millivolt appliances refer to the detailed

lighting instructions found on Page 15 (Eng-

lish) and Page 16 (French). Millivolt appliance

lighting instructions may also be found on the

pull-out lighting instruction labels located in the

control compartment (below glass door).

This appliance must be isolated from the

gas supply piping system (by closing its

individual manual shut-off valve) during

any pressure testing of the gas supply

piping system at test pressures equal to

or less than 1/2 psig (3.5 kPa).

This appliance and its individual shut-off

valve must be disconnected from the gas

supply piping system during any pressure

testing of that system at pressures greater

than 1/2 psig (3.5 kPa).

CONTROL COMPARTMENT ACCESS

Pull down hinged door to access control

compartment (see Figure 3).

Control Compartment Access

Pull down hinged door to access control compartment

Pull down lower

louver (hinged)

Side View of Insert

Figure 3

Figure 4

Burner Off/on Switch and Rheostat Location

If optional surround is installed

Burner Off/On

Switch

Rheostat

(blower

speed

control)

Left Front

surround

Panel

Units with Beveled Surround

Units with Flat Surround

Left Front

surround

Panel

Rheostat

(blower

speed

control)

Burner Off/on

Switch