9

If the burner flame appearance differs greatly

from what is shown in Figure 13 (see Burner

Flame Appearance), some adjustment from

the factory setting for the air shutter gap may

be necessary (to compensate for variables

in the installation and fuel such as, BTU

value/composition, gas pressure, specific

gravity of gas, altitude, etc.).

See Table 5 for Burner Air Shutter Adjust-

ment Guidelines.

Initially, always position the air shutter to the

factory setting as shown in Figure 14 (adjust-

ment rod is located in the lower control area).

This can be done by moving the adjustment

rod up or down accordingly. Allow the burner

to operate for at least 15 minutes. Observe

the flame continuously. If it appears weak

or sooty as previously described, adjust the

air shutter to a more open position until the

proper flame appearance is achieved.

Burner Adjustment Procedure

Burner Air Shutter Adjustment

Adjustment Rod Up

(1/8" Open Position)

Air Shutter

Burner Tube

Adjusting Set Screw

Adjustment Rod Down

(full open position)

Figure 14

MAIN BURNER FACTORY AIR

SHUTTER OPENING SETTING

Model

Gas Type

Air Shutter Gap

EBVI30 Natural Gas 5/16" (7.94mm)

Propane

1/" (1.7mm)

EBVI5 Natural Gas 1/16" (1.59mm)

Propane

1/" (1.7mm)

WARNING

Air shutter adjustment should

only be performed by a qualified

professional service technician.

CAUTION

The adjustment rod and nearby

appliance surfaces are hot. Exer-

cise caution to avoid injury while

adjusting flame appearance.

CAUTION

Carbon will be produced if the air shutter is closed too much. Any

damage due to carboning resulting from improperly setting the air

shutter is not covered under the warranty.

LOGS, VERMICULITE AND EMBERS

Carefully install the seven-piece log set into the firebox as shown in these instructions. All

logs should fit onto corresponding pins and/or log stoppers. This will ensure a proper flame

and safe combustion.

Note: Place some vermiculite around burner before installing logs (see Figure 24). The entire

bag of vermiculite will NOT be used.

The following chart is provided to aid you in achieving the correct air shutter adjustment

for your installation.

Table 5

Air Shutter Adjustment Guidelines

Amount of

Primary Air

Flame Color

Air Shutter

Adjustment

If air shutter is
closed too far

Flame will be orange Air shutter gap should

be increased

If air shutter is open
too far

Flame will be blue

Air shutter gap should
be decreased

WARNING

If logs are not installed according to the directions shown here, flame

impingement and improper combustion could occur and result in soot

and/or excessive production of carbon monoxide (CO) - a colorless,

odorless, toxic gas.

Top Left Log

Front Center Log

Top Right Log

Rear Log

Front Right Log

Front Left Log

Center Log

Figure 15

Installation Instructions