Lexmark 24XX-100 User Manual

Page 97

Advertising
background image

Repair Information

4-37

24xx

4. Remove the two screws [A] from the right upper feed roller

bracket. One screw also retains the upper feed roller ground
clip.

5. Pull the upper feed roller from the left bracket and out of the

printer.

6. Be sure to perform the Printhead-to-Platen Gap Adjustment

procedure. Go to

“Printhead-to-Platen Gap Adjustment” on

page 4-2

.

Advertising