Installation, Paralleling – Lincoln Electric IDEALARC CV-305 User Manual
Page 11
INSTALLATION
A-5
A-5
IDEALARC® CV-305
PARALLELING
The CV-305 is not designed to be paralleled with
another C-305 or with any other power source.
CONNECTION OF AUXILIARY EQUIPMENT
TO THE WIRE FEEDER RECEPTACLE
Occasionally, it may be necessary to make connection
to the circuits present in the 14-pin wire feeder recep-
tacle.
These circuits, such as the auxiliary voltage,
contactor,
and
remote
control
circuits,
may
be
accessed with a K867 Universal Adapter. This adapter
plugs into the receptacle and provides the user with
short wire leads for connections. Refer to the instruc-
tions provided with the K867, as well as the wiring dia-
gram for the CV-305 power source, for details on mak-
ing those connections.
For your convenience, wire
feeder connection details are shown in the DIAGRAM
section.
NOTE:
If you intend to use a standard Lincoln wire
feeder, order the appropriate input cable for
the specific feeder. It will make all of the con-
trol and power connections between the CV-
305 and the wire feeder WITHOUT the need
for a K867 Universal Adapter.