TROUBLESHOOTING & REPAIR

F-34

F-34

IDEALARC® CV-305

2ms

1V

0 Volts

CH1

This is the typical SCR gate pulse voltage

waveform. The machine was in an open cir-

cuit condition (no load) and operating prop-

erly. Note that each vertical division repre-

sents 1 volt and that each horizontal division

represents 2 milliseconds in time.

Note: Scope probes connected at SCR gate

and cathode: (+) probe to gate, (-) probe to

cathode.

Volts/Div . . . . . . . . . . . . . . . . . . .1 V/Div.

Horizontal Sweep

. . . . . . . . . .2 ms/Div.

Coupling . . . . . . . . . . . . . . . . . . . . . .DC.

Trigger

. . . . . . . . . . . . . . . . . . . .Internal.

SCOPE SETTINGS

TYPICAL SCR GATE VOLTAGE WAVEFORM