Lenovo 6446 User Manual

Page 93

Advertising
background image

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

LED

Description

Action

PS

2

The

power

supply

in

bay

2

has

failed.

Attention:

In

a

dc

power

environment,

only

trained

service

personnel

other

than

Lenovo

service

technicians

are

authorized

to

connect

or

disconnect

power

to

the

dc

power

supply

and

to

remove

and

install

a

dc

power

supply.

See

the

documentation

that

comes

with

each

dc

power

supply.

1.

Make

sure

that

the

power

supply

is

correctly

seated.

2.

Replace

the

failed

power

supply.

CPU

A

microprocessor

has

failed.

1.

Make

sure

that

the

failing

microprocessor,

which

is

indicated

by

a

lit

LED

on

the

system

board,

is

installed

correctly.

See

the

User

Guide

on

the

ThinkServer

Documentation

DVD

for

information

about

installing

a

microprocessor.

2.

Call

for

service.

VRM

An

error

occurred

on

the

microprocessor

voltage

regulator

module

(VRM).

1.

Replace

the

VRM.

2.

Call

for

service.

CNFG

A

hardware

configuration

error

has

occurred.

1.

Check

the

microprocessors

that

were

just

installed

to

make

sure

that

they

are

compatible

with

each

other

and

with

the

VRM

(see

“Installing

an

additional

microprocessor”

on

page

18

for

compatiblity

requirements).

2.

(Trained

service

technician

only)

Replace

an

incompatible

microprocessor.

3.

Check

the

system

error

logs

for

information

about

the

error.

Replace

any

components

that

are

indicated.

(Use

the

Configuration/Setup

Utility

program

to

view

the

error

logs.)

MEM

A

memory

error

has

occurred.

Replace

the

failing

DIMM,

which

is

indicated

by

the

lit

LED

on

the

system

board.

NMI

A

machine

check

error

has

occurred.

Check

the

system-error

log

for

information

about

the

error.

(Use

the

Configuration/Setup

Utility

program

to

view

the

error

logs.)

S

ERR

Reserved.

SP

The

service

processor

has

failed.

Attention:

In

a

dc

power

environment,

only

trained

service

personnel

other

than

Lenovo

service

technicians

are

authorized

to

connect

or

disconnect

power

to

the

dc

power

supply.

See

the

documentation

that

comes

with

each

dc

power

supply.

1.

Remove

power

from

the

server;

then,

reconnect

the

server

to

power

and

restart

the

server.

2.

Update

the

firmware

on

the

BMC.

3.

If

a

Remote

Supervisor

Adapter

II

SlimLine

is

installed,

update

the

firmware;

if

the

problem

remains,

replace

the

adapter.

4.

Call

for

service

DASD

A

hard

disk

drive

error

has

occurred.

1.

Check

the

LEDs

on

the

hard

disk

drives

and

replace

the

indicated

drive.

2.

Call

for

service.

Chapter

5.

Solving

problems

79