Replacing the serveraid sas controller, Replacing, Serveraid – Lenovo 6446 User Manual

Page 43: Controller

Advertising
background image

Replacing

the

ServeRAID

SAS

controller

A

ServeRAID

SAS

controller

can

be

installed

only

in

a

dedicated

slot

on

the

system

board.

The

server

comes

with

a

ServeRAID-8k-l

SAS

Controller

installed.

Note:

The

ServeRAID-8k-l

SAS

Controller

does

not

have

a

battery.

To

replace

the

ServeRAID-8k-l

SAS

Controller

with

a

ServeRAID-8k

SAS

Controller,

complete

the

following

steps:

1.

Read

the

safety

information

that

begins

on

page

v

and

the

“Installation

guidelines”

on

page

7.

2.

Turn

off

the

server

and

peripheral

devices

and

disconnect

all

power

cords

and

external

cables

(see

“Turning

off

the

server”

on

page

39).

Attention:

In

a

dc

power

environment,

only

trained

service

personnel

other

than

Lenovo

service

technicians

are

authorized

to

connect

or

disconnect

power

to

the

dc

power

supply.

See

the

documentation

that

comes

with

each

dc

power

supply.

3.

Remove

the

cover

(see

“Removing

the

cover”

on

page

9).

4.

Remove

the

riser-card

assembly

and

the

air

baffle

over

the

DIMMs.

See

the

User

Guide

for

more

information.

5.

Locate

the

ServeRAID-8k-l

SAS

controller

on

the

system

board.

Attention:

To

avoid

breaking

the

retaining

clips

or

damaging

the

connectors,

handle

the

clips

gently.

6.

Open

the

retaining

clip

on

each

end

of

the

connector.

7.

Lift

the

ServeRAID-8k-l

SAS

controller

out

of

the

connector.

8.

Touch

the

static-protective

package

that

contains

the

new

ServeRAID-8k

SAS

controller

to

any

unpainted

metal

surface

on

the

server.

Then,

remove

the

ServeRAID-8k

SAS

controller

from

the

package.

Chapter

2.

Installing

optional

devices

29

Advertising