Intermittent problems, Intermittent, Problems – Lenovo 6446 User Manual

Page 81

Advertising
background image

Intermittent

problems

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Symptom

Action

A

problem

occurs

only

occasionally

and

is

difficult

to

diagnose.

1.

Make

sure

that:

v

All

cables

and

cords

are

connected

securely

to

the

rear

of

the

server

and

attached

devices.

Attention:

In

a

dc

power

environment,

only

trained

service

personnel

other

than

Lenovo

service

technicians

are

authorized

to

connect

or

disconnect

power

to

the

dc

power

supply.

See

the

documentation

that

comes

with

each

dc

power

supply.

v

When

the

server

is

turned

on,

air

is

flowing

from

the

fan

grille.

If

there

is

no

airflow,

the

fans

are

not

working.

This

can

cause

the

server

to

overheat

and

shut

down.

2.

Check

the

system

event/error

log

or

BMC

system

event

log

(see

“Error

Logs”

in

the

Hardware

Maintenance

Manual

).

The

server

resets

(restarts)

occasionally

1.

If

the

reset

occurs

during

POST

and

the

POST

watchdog

timer

is

enabled

(click

Advanced

Setup

-->

Baseboard

Management

Controller

(BMC)

Setting

-->

BMC

Post

Watchdog

in

the

Configuration/Setup

Utility

program

to

see

the

POST

watchdog

setting),

make

sure

that

sufficient

time

is

allowed

in

the

watchdog

timeout

value

(

BMC

POST

Watchdog

Timeout

).

See

the

User

Guide

for

information

about

the

settings

in

the

Configuration/Setup

Utility

program.

If

the

server

continues

to

reset

during

POST,

see

the

“POST”

and

“Diagnostic

programs”

sections

in

the

Hardware

Maintenance

Manual

.

2.

If

the

reset

occurs

after

the

operating

system

starts,

disable

any

automatic

server

restart

(ASR)

utilities,

such

as

the

IBM

Automatic

Server

Restart

IPMI

Application

for

Windows,

or

ASR

devices

that

may

be

installed.

Note:

ASR

utilities

operate

as

operating-system

utilities

and

are

related

to

the

IPMI

device

driver.

If

the

reset

continues

to

occur

after

the

operating

system

starts,

the

operating

system

might

have

a

problem;

see

“Software

problems”

on

page

76.

3.

If

neither

condition

applies,

check

the

system

event/error

log

or

BMC

system

event

log

(see

“Error

Logs”

in

the

Hardware

Maintenance

Manual

).

Chapter

5.

Solving

problems

67