Basic Controller Programming

Programming Overview

The Controller can be programmed with various options for the operator.
The programming fields are defined as “functions” that have “options”.
To make setup easier for the installer, the Controller’s programming is
divided into two groups: basic and advanced. The basic programming
group contains the functions commonly used in most swing gate
installations. The advanced programming group contains functions less
commonly used (i.e. dual gate stagger delay, maximum run timer, etc.).

Entering Programming Mode

Enter programming mode by pressing the

UP and DOWN buttons

together for one second. While in programming mode the

PROGRAM

indicator will light.

Exiting Programming Mode

Exit programming mode at any time by pressing the

UP and DOWN

buttons together. The Controller will automatically exit programming
mode after three minutes of inactivity.

Programming Keystrokes

(Typical Programming Method)
While in programming mode, press the

UP or DOWN buttons to scroll

through the programming functions. When the desired function is
displayed press the

ENTER button to display the currently set option for

the function.

When an option is displayed, the decimal points are lit.

To change the option, press and hold the

ENTER button for 1 second. To

indicate that an option is ready to be changed, the display will flash. While
the display is flashing, press the

UP or DOWN button to display the other

options available for that function.
When the desired option is displayed, press the

ENTER button to store it

into memory. To select another function, press

ENTER, UP, or DOWN.

Left or Right Hand Operation

In typical installations, the LRA pulls the gate to open it inward.

Set the

Controller for right hand operation regardless if the installation is a
left hand or right hand gate.
This will make the open limit switch on the
motor end of the operator.
In some installations, the LRA pushes the gate to open it outward.

Set

the Controller for left hand operation regardless if the installation is
a left hand or right hand gate.
This will make the close limit switch on
the motor end of the operator.

Dual Gate Enable

The factory default is for single gate operation. For dual gate operation,
wire the two gate controllers together through the

COMM LINK terminals

(see Page 20) and enable dual gate operation with this programming
step. It is suggested that each controller be programmed separately, then
connected to the COM-LINK.

NOTE: The Mid-travel Stop feature is disabled when dual gate
operation is enabled for paired units.

Auto Close Timer

The factory default turns off the Auto Close Timer. The timer can be set
from 1 to 59 seconds and from 1 to 9 minutes. When the Auto Close
Timer is set, after opening, the gate will wait for the length of the Auto
Close Timer then close automatically.

PRESS DOWN AND UP

BUTTONS TOGETHER

FOR ONE SECOND

PROGRAM INDICATOR

WILL LIGHT WHEN SYSTEM

IS IN PROGRAM MODE

PROGRAM

INDICATOR

AND

DOWN

UP

ENTERING

PROGRAMMING

FUNCTION

LEFT HAND

RIGHT HAND

"RL"

FOR PULL-TO-OPEN INSTALLATIONS

LEAVE THE CONTROLLER SET FOR

RIGHT HAND OPERATION

FOR PUSH-TO-OPEN INSTALLATIONS

SET THE CONTROLLER FOR LEFT

HAND OPERATION

LEFT HAND LIMITS FOR

PUSH-TO-OPEN INSTALLATIONS

(GATE SWINGS OUT TO OPEN)

RIGHT HAND LIMITS FOR

PULL-TO-OPEN INSTALLATIONS

(GATE SWINGS IN TO OPEN)

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

FUNCTION

DUAL GATE INSTALLATION

SINGLE GATE INSTALLATION

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

SINGLE GATE

DUAL GATE

"PM"

PRESS UP OR DOWN

TO SCROLL DISPLAY

THROUGH FUNCTIONS

PRESS ENTER FOR

ONE SECOND TO

SELECT OPTION

(THE DISPLAY

WILL FLASH)

PRESS UP

OR DOWN

TO CHANGE

OPTION

ENTER

PROGRAMMING

KEYSTROKES

SELECT

FUNCTION

CURRENTLY

SET OPTION

OPTION READY

TO CHANGE

PRESS ENTER TO

DISPLAY CURRENTLY

SET OPTION

CHOOSE

OPTION

OR

UP

DOWN

OR

UP

DOWN

OPTION

STORED

PRESS ENTER

TO STORE

OPTION

SELECT

FUNCTION

ENTER

ENTER

ENTER

OR

UP

DOWN

OR

PRESS UP, DOWN

OR ENTER SELECT

NEXT FUNCTION

FUNCTION

SET TIMER VALUE

1 TO 59 SECONDS

AUTO CLOSE TIMER DISABLED

SET TIMER VALUE
1 TO 9 MINUTES

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

AUTO CLOSE

TIMER

"AC"

Advertising