Lennox Hearth B-MNC0353VDE User Manual

Page 25

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

25

Combustible
Finished Wall
Materials

This Area Must Remain
Clear of Combustible
Materials

Top of Appliance

1" Min

(25 mm)

Spacer

Louver Face Models

Top of Door Frame

Combustible

material

may touch the

appliance top.

Hood must be installed as shown.

Louvers

Combustible

materials not

allowed below

this point on

the face of the

appliance.

Combustible

Finished Wall

Materials

This Area Must Remain

Clear of Combustible

Materials

Top of Appliance

1" Min

(25 mm)

Spacer

Clean Face Models

Top of Door Frame

Hood must be installed as shown.

Radiant panel

Combustible

material

may touch the

appliance top.

Combustible

materials not

allowed below

this point on

the face of the

appliance.

R

E

N

R

U

B

N

I

A

M

G

N

I

T

T

E

S

G

N

I

N

E

P

O

R

E

T

T

U

H

S

Y

R

O

T

C

A

F

s

l

e

d

o

M

s

a

G

l

a

r

u

t

a

N

)

m

m

(

s

e

h

c

n

i

s

a

G

e

n

a

p

o

r

P

)

m

m

(

s

e

h

c

n

i

0

3

5

3

V

D

E

8

/

1

)

2

.

3

(

8

/

3

)

5

.

9

(

5

3

0

4

V

D

E

)

5

.

9

(

8

/

3

0

4

5

4

V

D

E

)

5

.

9

(

8

/

3

Air Shutter

Opening

Burner

Venturi

Tube

Air

Shutter

Door

Orifice

Increase

Air Shutter

Opening

Decrease

Air Shutter

Opening

Air Shutter

Adjusting

Arm

Figure 50

Figure 51

Figure 52

Burner Adjustment

Leave the control knob in the ON position and
the remote switch OFF. Close the lower control
compartment door.

Step 10. BURNER ADJUSTMENTS

Flame Appearance and sooting

Proper flame appearance is a matter of taste.
Generally, most people prefer the warm glow of
a yellow to orange flame. Appliances operated
with air shutter openings that are too large will
exhibit flames that are blue and transparent.
These weak, blue and transparent flames are
termed anemic. If the air shutter opening is too
small sooting may develop.

Sooting is indicated by black puffs developing
at the tips of very long orange flames. Sooting
results in black deposits forming on the logs,
appliance inside surfaces and on exterior sur-
faces adjacent to the vent termination. Sooting
is caused by incomplete combustion in the
flames and lack of combustion air entering the
air shutter opening. To achieve a warm yellow
to orange flame with an orange body that does
not soot, the shutter opening must be adjusted
between these two extremes.

No smoke or soot should be present. Reposi-
tion the logs if flames impinge on any of them.

If the logs are properly positioned and sooting
conditions exist, the air shutter opening on the
main burner tube should be adjusted. Normally,
the more offsets in the vent system, the greater
the need for the air shutter to be opened further.

Observe the flame continuously. If it appears
weak or sooty as previously described, adjust the
air shutter by pushing or pulling on the adjust-
ment rod until the flame appearance is as de-
sired. The adjustment rod and associated ad-
justable air shutter is patented technology.
Flame adjustments can be made quickly and
accurately to taste without the need of disas-
sembling the appliance and waiting for 30
minutes after each adjustment.

Propane models may exhibit a flame pattern
that may candle or appear stringy. If this is
problematic or persists as the appliance is
continually operated, adjust the air shutter
closed as described in the previous paragraphs.
Operate the appliance for a period of time as the
effect diminishes, ensuring that the appliance
does not develop sooty flames. When satisfied
that the appliance operates properly, proceed
to finish the installation.

WARNING: AIR SHUTTER ADJUST-
M E N T S H O U L D O N L Y B E P E R -
FORMED BY A QUALIFIED PROFES-
SIONAL SERVICE TECHNICIAN.

IMPORTANT: ENSURE THAT THE FRONT
GLASS PANEL IS IN PLACE AND SEALED
DURING ADJUSTMENT.

CAUTION: THE AIR SHUTTER DOOR
AND NEARBY APPLIANCE SURFACES
ARE HOT. EXERCISE CAUTION TO
AVOID INJURY WHILE ADJUSTING
FLAME APPEARANCE.

FINISHING REQUIREMENTS
Wall Details

Complete finished interior wall. To install the
appliance facing flush with the finished wall,
position framework to accommodate the thick-
ness of the finished wall (

Figures 51 and 52 )

Step 11. HOOD INSTALLATION

All of these appliances must have hoods
installed prior to operating.

On all clean face units, slide the hood into the slots
on the lower edge of the radiant panel

(Figure 51 ).

On louvered face units, slide the hood into the slots
on the lower edge of the cabinet top

(Figure 52 ).

To adjust the flame, rotate the adjustment rod
toward the back or toward the front of the fire-
place (rod located in the lower control area).
Position the air shutter to the factory setting as
shown in the table in

Figure 50. Allow the burner

to operate for at least 15 minutes.

Advertising