NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 2 - Top View, Parallel Installation

Figure 3 - Side View, Alcove and Parallel

Installations

Footnotes:

1- These dimensions to the stove body are for reference only. Actual distances should be measured from the stove’s flue collar.

2- Minimum noncombustible hearth pad dimensions.

3- Shield shall be attached to the rear of the stove pipe with a 1” air space and must run from the top of the stove to the ceiling.

4- Not applicable to alcove installations.

5- In corner applications, when installed at minimum back wall clearances, the required floor protection is dimensioned off the back plane of the stove, therefore the

floor protection required off the back corners (at a 45 degree angle) only needs to extend to the wall. This situation will only occur in CANADA installations.

6- Reference dimension only, to assist in planning the installation.

Clearances to connector pipe shall be measured from the flue collar of the stove.

PIPE

INSTALLATION

A

B (1)

C

D (1)

E†

F (1,4)

G (4)

H (2)

6” Single Wall

Residential

18”

(450mm)

15-1/2”

(394mm)

26”

(660mm)

16”

(406mm)

8”

200mm

11”

(279mm)

21”

(533mm)

USA-37-1/4”

CAN-1200mm

6” Double Wall Residential or Alcove

or Mobile Home*

12”

(305mm)

9-1/2"

(241mm)

23”

(584mm)

13”

(330mm)

8”

200mm

11”

(279mm)

21”

(533mm)

USA-37-1/4”

CAN-1200mm

8” Single Wall

Residential

23”

(584mm)

20-1/2”

(521mm)

28”

(711mm)

18”

(450mm)

8”

200mm

13”

(330mm)

23”

(584mm)

USA-37-1/4”

CAN-1200mm

8” Double Wall Residential or

Mobile Home*

16”

(406mm)

13-1/2”

(343mm)

25”

(635mm)

15”

(381mm)

8”

200mm

12”

(305mm)

22”

(559mm)

USA-37-1/4”

CAN-1200mm

8” Double Wall Alcove - Residential

or Mobile Home*

16”

(406mm)

28”

(711mm)

28”

(711mm)

18”

(450mm)

8”

200mm

N/A

N/A

USA-37-1/4”

CAN-1200mm

PIPE

INSTALLATION

I (6)

J (2)

K

L (5)

M

T (6)

6” Single Wall

Residential

USA-52-3/4”

CAN-1391mm

USA-37-1/2”

CAN-1118mm

USA-16”

CAN-450mm

USA-0”

CAN-200mm

N/A

USA-66”

CAN-1727mm

6” Double Wall

Residential or Alcove

or Mobile Home*

USA-46-3/4”

CAN-1238mm

USA-37-1/2”

CAN-1118mm

USA-16”

CAN-450mm

USA-0”

CAN-200mm

84” 2134MM

USA-66”

CAN-1727mm

8” Single Wall

Residential

USA-57-3/4”

CAN-1518mm

USA-37-1/2”

CAN-1118mm

USA-16”

CAN-450mm

USA-0”

CAN-200mm

N/A

USA-68-3/4”

CAN-1797mm

8” Double Wall

Residential or

Mobile Home*

USA-50-3/4”

CAN-1340mm

USA-37-1/2”

CAN-1118mm

USA-16”

CAN-450mm

USA-0”

CAN-200mm

N/A

USA-67-1/4”

CAN-1759mm

8” Double Wall

Alcove - Residential

or Mobile Home*

USA-50-3/4”

CAN-1340mm

USA-37-1/2”

CAN-1118mm

USA-16”

CAN-450mm

USA-0”

CAN-200mm

84” 2134MM

USA-67-1/4”

CAN-1759mm

† USA=8" (200mm) from door opening, Canada=8" (200 mm) from sides and back of unit

u

Dimensions to Stove Body

* Mobile Home - USA only
Clearances may only be reduced by means approved by the regulatory authority.

L

C

D

†E

†E

K

Floor Protector

H

I

J

B

A

M

96” Min.

I

Floor Protection

K

T

J

H

Floor

Protection

F

F

G

G

Figure 4 - Top View Corner Clearance,

Stove and Flue to Wall

48”

Max.

Depth

8” Ø

Flue Collar

INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 AND 4