Figure 1 - Gas Supply Entry Points

10.0 PREPARING THE APPLIANCE

IMPORTANT NOTE: All gas piping must be done by a licensed plumber

or gas fitter and must conform to the requirements of the National Fuel

Gas Code NFPA 54 / ANSI Z223.1 - latest edition

Gas connection: The heater gas inlet connection is 3/8” NPT at the

regulator, located below the burner, in the center of the heater.

There are four possible entry points for the gas supply pipe-work to

enter the appliance firebox. These entry points are ‘knock out’ type holes

(shown in Figure 1).

Non-concealed gas connections may be made using the entry points

on the sides or base of the firebox. A concealed gas connection may be

made using the knock out hole in the center back of the firebox. Select

the most appropriate entry point and knock out the relevant hole.

If a concealed gas connection is to be made, the supply pipe should

always be sleeved through walls and floors using the shortest possible

route.

For concealed supply pipe routing, pipes must (where possible) be vertical

and providing there is sufficient wall thickness available, they should be

placed in pipe chases. Horizontal pipe runs should be avoided. Prior to

chasing a solid wall, an inspection should be made to note the proximity

of any cables/sockets outlets which may already be buried. Pipes must

be secured using suitable clips and protected against corrosion. Ideally

factory finished protected pipe-work and fittings should be used. Joints

should be kept to a minimum and compression fittings must not be used.

The pipe-work installation must be tested for soundness before any

protection is applied and/or the pipe-work and fittings are buried.

11.0 MOUNTING THE APPLIANCE

After having selected the final mounting position of the appliance, taking

into account the site requirements as specified in section 9.0 of these

instructions, the integrity of the wall, and the feasibility of the proposed

supply pipe routing, the appliance firebox may be secured to the wall.

WARNING

The wall where the appliance is to be installed must

be capable of long-term support of the total load of

the appliance. Measures should also be taken to

ensure sufficient strength to withstand the force of

earthquakes, vibration and other external forces.

To ensure customer safety, be sure to design the installation so that the

strength of both the wall and any wall fixings used are sufficient. Lennox

Hearth Products assumes no responsibility for injuries and damages that

may occur due to improper installation or handling.

The appliance should not be installed until all dry wall sanding and wall

painting has been completed.

Incorrect installation can cause the appliance to fall from the wall and

cause injury. Do not block the ventilation holes of the appliance. The

wall onto which the appliance is installed must be flat.

Install only on a vertical surface. Avoid sloped surfaces. Installation

onto anything other than a vertical wall may result in fire, damage

or injury.

A full size fitting template is supplied to assist with wall-mounting.

Mark the positions shown as “Fixing Points” on the wall. If the appliance

is to be mounted on the inner leaf of a conventional cavity wall, or a solid

wall, drill four holes using a 5/16" masonry bit, to a depth of 1-11/16".

Insert the wall plugs provided. Note: Special "screw fixings" are not

required if installed directly into vertical studs. We recommend that

this appliance should be secured to a stud on at least one side while

the other side can be secured to the wall with the "screw fixings".

If the appliance is to be mounted on a dry lined wall or a timber framed

construction wall then special cavity screw fixings will be required which

are not supplied with this product. These should be constructed from

metal and not plastic.

If a concealed gas connection is to be made ensure the gas supply pipe

is in it’s final position and can enter the appliance in the correct position

when the appliance is hung on the wall.

Insert the wall-mounting screws into the top wall plugs, taking care to

leave the screws protruding approximately 3/8” from the wall. Now hang

the appliance onto these screws through the two keyhole shaped holes

in the back panel of the appliance.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

7

FIREBO

X OUTLINE

C

ONT

ORNO DE LA CAMARA DE C

OMBUSTION

POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL

COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED

PIERCE TEMPLATE TO MARK

HOLE POSITION ON WALL X 4

CENTRE LINE

CONCEALED GAS INLET

ENTRADA DE GAS OCULTA

FIXING POINTS

Elite

CVF

FIXING POINTS

PUNTOS DE SUJECION

PERFORE LA PLANTILLA PARA MARCAR

LA POSICION DE LOS 4 TALADROS EN LA PARED

PUNTOS DE SUJECION

LINEA DE CENTRO

WALL MOUNTED VENT FREE FITTING TEMPLATE

PLANTILLA PARA LA INSTALACION DE CHIMENEAS

DE PARED SIN SALIDA DE HUMOS

IMPORTANT

THIS APPLIANCE IS TO BE WALL HUNG ONLY.

DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE.

THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY.

DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE.

IMPORTANTE

ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED.

NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO.

ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION.

RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.

WARNING

CLEARANCES FROM COMBUSTIBLE MATERIALS

F860041/A

The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual
provided with the heater.

Note : Zero clearance from bottom of heater frame
required for hard combustible floors. Minimum 4”
clearance required to rugs or any fabric floor
coverings. REFER TO INSTRUCTION MANUAL

IMPORTANT : Fabrics, curtains and drapes are not
permited above the heater at any distance and within
20” of the heater sides. No combustible shelves of any
size are permitted above the heater.

Clearance to
combustible
sidewalls 4”
(both sides)

Clearance to combustible ceiling
32” measured from top of appliance
glass panel

Clearance in
front of
heater 20”

F860041/A

Deben mantenerse en todo momento los siguientes espacios
libres. El no hacerlo puede causar un riesgo de incendio.
Consulte el manual de instrucciones suministrado con este
aparato para obtener información completa.

Nota: No se requiere espacio libre desde el borde inferior del
marco del calentador en caso de pisos combustibles duros.
Se requiere un espacio mínimo de 4” entre el calentador y
cualquier alfombra, moqueta o revestimiento de suelo de
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.

IMPORTANTE: No se permite la colocación de telas, cortinas y

similares por encima del calentador a cualquier distancia, ni a

una distancia de 20” de los laterales del calentador. No se

permiten estantes combustibles de cualquier tamaño por

encima del calentador.

Espacio hasta
paredeslaterales
combustibles
4” (ambos lados)

El espacio de 32” hasta un techo
combustible se mide desde el borde
superior del panel de vidrio del aparato

Espacio libre
delante del
calentador 20”

ADVERTENCIA

ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES

DO 005860/0 - ISSUE A

20-1/4”

(515mm)

1-1/8” (28mm)

9-3/16” (234mm)

APPLIANCE OUTLINE

C

ONT

ORNO DE LA AP

ARA

TO

FocalPointFires Single 24/07/08

DO 005860/0 Iss-B

Lennox P23 Elite CVF fitting template

Ref. Paul West - Focal Point Fires

Artwork Size: W605 x H960

Figure 2

Advertising