1.3 S

ETUP

Read the Operation Manual before setting up the Life Fitness Treadmill. Place the treadmill where it
will be used before beginning the setup procedure.

E

LECTRICAL

P

OWER

R

EQUIREMENTS

The Life Fitness Treadmill requires a dedicated* line
according to the electrical configurations listed in the
chart below.

* One individual branch circuit for each treadmill per NEC article
210-21 (b) (1) and 210-23 (or other appropriate, country specific
electrical compliance guidelines). The hot, neutral and ground
wires must each be routed independently (not looped or tied to
other circuits.)" .

NOTE: Do not modify the plug provided with this
product. If the plug does not fit into an available elec-
trical outlet, have a proper outlet installed by a quali-
fied electrician.

G

ROUNDING

I

NSTRUCTIONS

This Life Fitness product must be properly grounded. If the unit malfunctions or breaks down, proper
grounding provides a path of least resistance for the electric current, which reduces the risk of shock
to anyone touching or using the equipment. Each unit is equipped with an electrical cord, which
includes an equipment grounding conductor and a grounding plug. The plug must be inserted into an
outlet that has been properly installed and grounded in accordance with all local codes and ordi-
nances.

A temporary adapter MUST NOT BE USED to connect this plug to a two-pole receptacle in
North America. If a properly grounded, 20-amp outlet is not available, one must be
installed by a qualified electrician. Models drawing 16 amps or more must be installed on
a dedicated line.

IL EST ABSOLUMENT INTERDIT d'employer un adaptateur temporaire pour brancher cette
fiche sur une prise bipolaire en Amérique du Nord. Si aucune prise de 20 A correctement
mise à la terre n'est disponible, en faire installer une par un électricien qualifié. Les mod-
èles utilisant 16 A ou plus doivent être branchés sur un circuit spécialisé.

DANGER:

A risk of electrical shock may result from improper connection of the

equipment-grounding conductor. Check with a qualified electrician if in doubt as to proper
grounding technique. DO NOT modify the plug provided with the product. If it will not fit
an electrical outlet, have a proper outlet installed by a qualified electrician. Any modifica-
tion to the electrical plug will result in a voided warranty.

DANGER:

Un branchement incorrect du conducteur de mise à la terre peut entraîner

des risques de décharge électrique. Consulter un électricien si des doutes subsistent quant à
la technique de mise à la terre. NE PAS MODIFIER la fiche fournie avec l'appareil. Si elle ne
s'adapte pas à une prise, faire installer une prise correcte par un électricien qualifié. Toute
modification à la fiche annule la garantie.