Step 16. Turn on gas supply and test for gas leaks using a gas leak test

solution (see Test Procedure on Page 18 of the Installation and

Operation Manual).

Step 17. Using a manometer, test the inlet and manifold gas pressure

per instructions in the Installation and Operation Manual (Page

18) and as shown in the following 2 tables.

Step 14. Reinstall the log set and glass door assembly. See Page 12

(Log Set Installation) and Page 25 (Door Assembly Installation)

in the Installation and Operation Manual.

Step 15. Light the appliance per the lighting instructions label on appliance

(located inside left door) or lighting instructions on Page 19 of

the Installation and Operation Manual. Inspect for proper pilot

and burner flame appearances (see Figures 15 and 16 below).

Also see Flame Color and Behavior and Inspect The Pilot System

For Proper Flame on Page 20 of the Installation and Operation

Manual.

Figure 16 - Burner Flame Appearance

No Blue Flame

Center

Soot at

Flame Tip

Dark Orange

Flame

IMprOpErLy

BurNING FLaME

Soot above

Flame Tip

No Soot at

Flame Tip

prOpErLy

BurNING FLaME

Semi-Transparent

yellow Flame

Blue Flame

Center

ports on pan

Burner assembly

Figure 15 - Proper Pilot Flame Appearance

Safety Label

Step 15.Remove the sticker covering the model on the label so that it

reads “Epic NG40” if orifice #31 is installed. Use the sticker

“Epic NG33” to cover “Epic NG40” on the label if orifice #36

is installed. The label is located on the inside of the left hand

door (see Figure 14).

Figure 13

Figure 14

Step 14. Before you secure the burner with screws, double check that

the orifice is positioned into the burner neck by feeling around

the back of the burner (see Figure 13). Then, lower the burner

so it sits flush on the burner supports and replace the 2 screws

removed in step 6 (see Figure 13).

reach behind burner and feel orifice to

ensure it is centered in the burner neck

Lower burner flush and reinstall

screws (indicated by arrows)

Burner

Burner

Inlet Gas Supply pressure

Fuel #

Minimum

Maximum

Desired

Nat.

Gas

5" wC/po. C.E

(1.24 kpa)

10.5" wC/po. C.E

(2.61 kpa)

7" wC/po. C.E

(1.74 kpa)

Manifold Gas Supply pressure

Fuel #

Low

high

Natural

Gas

(Lo) 1.7" wC/po. C.E

(0.42 kpa)

(hi) 3.5" wC/po. C.E

(0.87 kpa)

4

printed in u.S.a. © 2007 Lennox hearth products

p/N 775,235M rEv. C 03/2008

Lennox reserves the right to make changes at any time, without notice, in design,

materials, specifications, prices and also to discontinue colors, styles and products.

Consult your local distributor for fireplace code information.

1110 west Taft avenue • Orange, Ca 92865

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.

Advertising