10

2. Light appliance (follow lighting procedure on

lighting label in control compartment or see
homeowners manual).

3. Allow the burner to operate for at least 15 min-

utes while observing the fl ame continuously
to ensure that the proper fl ame appearance
has been achieved (see Figure 13 ). If the
following conditions are present, adjust
accordingly.

• If flame appears weak or sooty, adjust

the air shutter, incrementally, to a more
open position until the proper fl ame
appearance is achieved.

• If fl ame stays lowered blue, adjust the

air shutter, incrementally, to a more
closed position until the proper fl ame
appearance is achieved.

4. Leave the control knob (off/pilot/on) in the

ON position and the burner OFF/ON switch
OFF (& remote switches, if applicable).

5. When satisfi ed that the burner fl ame appear-

ance is normal, close the lower control
compartment door.

Adjustment Rod Positions
(when viewed from above)

Figure 14

Main Burner Factory Air Shutter

Opening Setting - All Models

Model

Natural

Gas

Propane

Gas

MPD35ST

1/8”

3.2mm

1/4”

6.4mm

Increase Shutter Opening
In This Direction

Decrease Shutter Opening
In This Direction

Note - Burners are

omitted in this

view for clarity.

Orifi ce

Air Shutter
Adjusting
Rod

Electronic Appliance Checkout

To light the burner, refer to the lighting instruc-
tions on Page 16. Ensure the igniter lights the
pilot. The pilot fl ame should engulf the fl ame
sensor as shown in Figure 16.

Figure 16

3/8" to 1/2"

(9 -13 mm)

Ground

Electrode

Flame Rod

Hot Surface

Igniter

Proper Flame

Adjustment

Pilot
Nozzels

Millivolt Appliance Checkout

The pilot fl ame should be steady, not lifting
or fl oating. Flame should be blue in color with
traces of orange at the outer edge.

The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" minimum (tip)
of the quick drop out thermocouple should be
engulfed in the pilot fl ame. The fl ame should
project 1" (25 mm) beyond the hood at all three
ports. See Figure 15.

To light the burner, refer to the lighting instruc-
tions on Page 15.

ELECTRONIC PILOT ASSEMBLY

Proper Pilot Flame Appearance

Figure 15

Thermocouple

Thermopile

Pilot
Nozzels

MILLIVOLT PILOT ASSEMBLY

3/8" Min.

(9 mm)

Igniter Rod

Hood

Proper Pilot Flame Appearance

With proper care and maintenance, your appli-
ance will provide many years of enjoyment. If
you should experience any problem, fi rst refer
to the troubleshooting guide in this manual.
If problem persists, contact your Lennox
distributor.