NSTALLATION

A gap of at least 2 inches (51 mm) depth must

be provided behind and along the entire width of

this unit to ensure sufficient ventilation. The area

of ventilation above the unit should be at least 18

square inches (116 cm2). The greater the area the

more economically the appliance will run.

1. When installing with standard kitchen units,

maximum depth of 22-13/16 inches (580 mm)

and decor panels of maximum 1/16 inch (2 mm)

thickness, the appliance can be set up right next

to the kitchen unit. The door protrudes 1-5/16

inches (34 mm) from the side of the kitchen unit

and 2 inches (51 mm) at the front. This enables

it to be opened and closed without difficulty.

2. When setting up the appliance next to a wall

(Fig. 4, 4), a minimum distance of 1-7/16 inches

(36 mm) must be provided on the hinge side

between the appliance and the wall (for the

handle when the door is open).

3. If you wish to attach the appliance to adjacent

units or to fit a spacer between the appliance

and the wall, please note the following:

• Verify that the door can open and close

properly.

Do not drill any holes in the side walls

in Figure 4. Liebherr refrigerator/freezer

combinations are equipped with a heating

element to eliminate condensation when units

are installed side by side. This element and

foamed components can be damaged.

Installing

- Figure 4

B

A

C

ca. 36

min.

200 cm

2

4

3

2

1

(1) Top unit

(2) Refrigerator/freezer

(3) Kitchen unit side panel

(4) Wall

A. 24-13/16" (630 mm)

B. 22-13/16" (580 mm)

C. 2" (51 mm)

Figure 4

The appliance can be installed in a row of kitchen

units. To adapt the height of the appliance to the

surrounding furniture a top unit

(Fig. 4, 1) can be

added.