Lennox Hearth GRANDVIEW P/N 506033-56 User Manual

Page 2

Advertising
background image

2

Printed in U.S.A. © 2011 Lennox hearth Products

P/N 506033-56 Rev. NC 08/2011

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.

Lennox Hearth Products reserves the right to make changes at any time, without notice, in

design, materials, specifications, prices and also to discontinue colors, styles and products.

Consult your local distributor for fireplace code information.

Step 3. Install the four supplied allen screws into tinnerman nuts, leaving

loose. A 1/8” allen wrench will be necessary.

Step 4. Place blower keyhole mounting slots onto the four installed screws

and slide assembly downward, ensuring all mounting screws are

holding blower in place. Tighten all four screws snugly. NOTE*

POWER CORD WILL BE ON THE BOTTOM.

Step 5. Install temperature activated switch bracket into rectangle cutout,

in the upper right corner on rear of stove, with wires facing out-

ward from the actual firebox. Secure with the larger two supplied

allen head screws. A 5/32” allen wrench will be necessary. NOTE*

ENSURE TEMPERATURE ACTIVATED SWITCH IS MAKING FIRM,

FLAT CONTACT WITH SIDE OF FIREBOX.

Step 6. Plug power cord into 120V wall outlet.

Figure 2 - Installed Blower w/ Snap Switch

BLOWER OPERATION

The blower can be operated in either manual or automatic mode. When

operated automatically, the blower will turn on when the stove is hot, and

turn off when the stove is cool.

MANUAL OPERATION

Flip blower mode switch to the manual position (up) and adjust blower

speed dial to desired setting. to turn blower off, rotate blower speed dial

counter clockwise until it clicks “OFF”.

AUTO OPERATION

Flip blower mode switch to auto position and turn blower speed dial

clockwise until it clicks out of the “off” position. When the stove warms

up (approx. 15-20 Mins), the blower will automatically turn on (adjust

blower speed dial to desired speed setting. When the stove cools down,

the blower will automatically turn off.

Figure 3 - Blower Controls

1508 Elm hill Pike, Suite 108 • Nashville, TN 37210

Advertising