6. Shroud

1. Remove the fan. (Refer to section 5)
2. Remove the shroud. (See Figure 20)

3. Re-install the components by referring to the

removal procedure, above.

7. Overload Protector

1. Remove the cabinet. (Refer to section 2)

2. Remove the nut that fastens the terminal cover.

3. Remove the terminal cover. (See Figure 21)

4. Remove all the leads from the overload protec-

tor.

5. Remove the overload protector.

6. Re-install the components by referring to the

removal procedure, above.

8. Compressor

1. Remove the cabinet. (Refer to section 2)

2. Discharge the refrigerant system using a

Freon

TM

Recovery System.

If there is no valve to attach the recovery sys-
tem, install one (such as a WATCO A-1) before
venting the Freon

TM

. Leave the valve in place

after servicing the system.

3. Remove the overload protector. (Refer to sec-

tion 7)

4. After purging the unit completely, unbraze the

suction and discharge tubes at the compressor
connections.

5. Remove the 3 nuts and the 3 washers which

fasten the compressor.

6. Remove the compressor. (See Figure 22)

7. Re-install the components by referring to the

removal procedure, above.