background image

Service Manual 29

Troubleshooting Guide

• Check the Fuse.
• Check the wiring diagram.

Is the

Trans input power AC 115V?

(208/230V for LWL1230WAL)

Is the Trans output power

about AC 14V?

Is the Trans. output shorted?

Is output Voltage of IC01D

DC 12V?

Is output Voltage of IC02D

DC 5V?

Is the voltage No.40 of Micom

DC 5V?

Replace AC PCB Ass'y.

Is the

connection between

AC and DC

OK?

Is the reset circuit OK?

(The No.14 of Micom is 5V.)

• Check the Fuse.
• Check the wiring diagram.

• Check the AC
PCB pattern.

• Replace the Trans.

• Replace D02D~D05D.
• Replace IC01D.

• Replace IC02D.

• Replace IC01A, C01A.

• Connect connector
exactly.

• Check the PCB
pattern.

NO

NO

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

NO

YES

Possible Trouble 1

The unit does not operate.

ElectrIc Parts