Installation – Lincoln Electric COOL ARC IM911 User Manual

Page 11

Advertising
background image

A-4

INSTALLATION

COOL ARC® 40

A-4

HORIZONTAL INSTALLATION ON THE
TOP OF A POWER SOURCE

For proper installation, follow the instructions provided
with the K559-2 Cooler Horizontal Mounting Bracket
Kit. The cooler is secured to the power source lift bale.
Reference the table below for a list of power sources
that allows the COOL ARC® 40 to be mounted hori-
zontally on top.

VERTICAL INSTALLATION ON POWER
SOURCE WITH A DUAL CYLINDER
UNDERCARRIAGE.

For proper installation, follow the instructions provided
with the K559-3 Cooler Vertical Mounting Bracket Kit.
The cooler is securely mounted to the dual cylinder
support bracket. Reference the table below for a list of
power sources and dual cylinder undercarriages that
allows the COOL ARC® 40 to be mounted vertically at
the rear of the machine on the gas bottle rack.

If the COOL ARC® 40 is not securely mounted
horizontally on top of a power source or vertically
on a dual cylinder undercarriage, THE COOL
ARC® 40 MUST BE OPERATED IN THE HORIZON-
TAL POSITION. This will prevent the cooler from
being accidentally tipped over.
------------------------------------------------------------------------

Remove the connector nut from the INLET hose by
making a straight cut 6-12 mm (1/4"-1/2") away from
the end of the nipple located inside of the hose. Take
the nipple and the connector nut ordered above and
insert the nipple into the connector nut so that the
threaded end of the connector nut points away from
the barbed end of the nipple. Twist the barbed end of
the nipple into the hose until the shoulder of the nip-
ple is flush with the end of the hose. Secure the hose
onto the nipple with the hose clamp to insure that the
connection is watertight. No water can leak from the
connection if it is properly attached. Repeat the proce-
dure for the OUTLET hose. When complete, follow the
connection procedure detailed above for connecting
the hoses to the COOL ARC® 40 fittings.

The connector and nipple listed fit tightly onto 4.0 mm
( 5/32") to 4.8 mm (3/16") inner diameter hose, but if
clamped tightly to the hose, can fit up to a 6.4 mm
(.25”) inner diameter hose.

INPUT POWER CONNECTION

Plug the input power cord on the COOL ARC® 40 into
a standard 230V circuit breaker protected receptacle.

INSTALLATION ON UNDERCARRIAGE OR
POWER SOURCE

The COOL ARC® 40 can be mounted either horizon-
tally or vertically on a power source. To mount the
cooler horizontally, order the K559-2 Cooler
Horizontal Mounting Bracket. To mount the cooler ver-
tically on a power source with a dual cylinder under-
carriage, order K559-3 Cooler Vertical Mounting
Bracket.

WARNING

Power Source

CV-300
CV-400
CV-655

DC-250
DC-400

DC-600, DC-655

Square Wave TIG 275
Square Wave TIG 355

Power Wave 455

Power MIG 255

K559-3

Cooler Vertical Mounting

Bracket on a Dual

Cylinder Undercarriage

K874 Undercarriage

Not Available
Not Available
Not Available
Not Available
Not Available

K932-1 Undercarriage

Not Available

K1570-1 Undercarriage

Not Available

K559-2

Cooler Horizontal

Mounting Bracket

Can be used On Top

of a Power Source

Yes
Yes
Yes
Yes
Yes
Yes

No

Yes

No
No

Advertising