Installation – Lincoln Electric COOL ARC IM911 User Manual

Page 8

Advertising
background image

K2187-2 (COOL ARC® 40 230V International)

Via Continental European (SCHUKO)- PRONG PLUG

220-240VAC 50/60 Hz 1 Phase

1.3-1.7 Amps

2.0-2.4 Amps

60 psi (414 kPa) (4.14 bar)Max.

1.66 gal/min. (6.28 liter/min) Max.

53-57 psi (365-393 kPa)

.45-.60 gal/min. (1.7-2.3 liter/min)

2.0 ga. (7.6 liters)

For Use Above Freezing: Use Clean tap, distilled or de-ionized water.

For Use Below Freezing: Use 50% water and 50% pure ethylene glycol

(reagent or industrial grade) mixture.

DO NOT USE: Automotive anti-freeze that contains rust inhibitors or leak stoppers.
These coolants will damage the pump and block the small internal passageways of the
heat exchanger, affecting cooling performance. To acquire the proper coolant contact
a local welding distributor.
DO NOT USE: Pre-packaged welding industry coolants. These coolants may contain
oil-based substances, which attack the plastic components of the cooler. Once added
to the cooler, these substances are impossible to purge from the water lines and heat
exchanger.

46.5 lbs. (21.1 kg)

61.2 lbs. (27.8 kg)

9.03 in. (229.4mm)

9.10 in. (231.1mm)

31.99 in. (812.6mm)

34.26 in. (870.2mm)

A-1

INSTALLATION

COOL ARC® 40

A-1

Product No. / Model

Input

Current Draw @ 60Hz Input

Current Draw @ 50Hz Input

Maximum Operating Pressure and Flow Rate

(Open Flow, Without Welding Torch Restriction)

Typical Operating Pressure and Flow Rate

(With Welding Torch Restriction)

Reservoir Size

Recommended Coolant

Shipping

Weight

Reservoir
Full (Water)

L

W

Dimensions

H (Top Face)

H Top Handle)

TECHNICAL SPECIFICATIONS – COOL ARC® 40

EXPLANATION OF SYMBOLS THAT APPEAR ON THIS EQUIPMENT

OFF

OFF

O

ON

Advertising