Installation, Caution, A-5 installation of water cooled accessories – Lincoln Electric COOL ARC IM911 User Manual

Page 12: Figure 2, Figure 3, Figure 4, Figure 5, Cool arc® 40, Water cooled tig torch connection, Water cooled mig gun connection

Advertising
background image

A-5

INSTALLATION

COOL ARC® 40

A-5

INSTALLATION OF WATER COOLED
ACCESSORIES

After following the installation instructions above, the
COOL ARC® 40 is ready for connection to a water-
cooled accessory.

WATER COOLED TIG TORCH AND MIG GUN
Follow Figure 2 when using the COOL ARC® 40 with
water-cooled TIG torches. Follow Figure 4 when
using the COOL ARC® 40 with water-cooled MIG
gun. Consult the manufacturer's instruction manual
when using the COOL ARC® 40 with other water-
cooled TIG and MIG accessories.

CONNECTION TO WIRE FEEDERS
Follow Figure 3 when using the COOL ARC® 40 in
conjunction with a wire feeder. Because the COOL
ARC® 40 requires continuos flow the feeder will need
to have pass-through water hoses installed in order to
operate with the COOL ARC® 40. DO NOT USE A
WATER SOLENOID VALVE with the COOL ARC®
40. Water pass-through connection kits are available
for wire feeders. Refer to product literature or the wire
feeder's instructions manual for kit availability and fur-
ther connection details. It is not required to run the
water lines through the wire feeder. If pass-through
water hoses are unavailable, connect the MIG gun as
shown in Figure 4.

DO NOT USE A WATER SOLENOID VALVE with
the COOL ARC® 40. When a solenoid valve clos-
es, the pump dead-head, causing the pump to
heat up and will lead to premature failure of the
pump.
------------------------------------------------------------------------

K529-10 POWER INPUT CABLE WITH WATER
AND GAS HOSES
This cable assembly includes a (1) power cable, (1)
control cable, (1) gas hose and (2) water hoses to
connect a power source to a wire feeder. The cable
length is 3.05 m (10 Ft.). The water hoses have 5/8"-
18 left hand male hose fittings and the gas hose has a
5/8"-18 right hand male hose fitting. The cable and
hose lengths are designed to connect a wire feeder to
a COOL ARC® 40 that is vertically mounted at the
rear of a power source on a dual cylinder undercar-
riage.

Refer to Figure 5 for an illustration of this connection.

CAUTION

REGULATOR
FLOWMETER

GAS*

ARGON GAS

CYLINDER

COOLANT

OUT

COOLANT

IN

COOLANT*

GAS

COOLANT*

GAS

IN OUT

COOLANT

GAS

TO WORK

POWER / COOLANT

POWER CABLE ADAPTER*

TIG TORCH

*INCLUDED IN

FEMALE TO FEMALE*
CGA FITTING

KP504 HOOK-UP KIT

POWER SOURCE

COOLANT

IN

COOLANT

OUT

COOLANT

COOLANT

GUN CABLE

KP504-WATER HOSES AND

FEMALE TO FEMALE 5/8" LH

CGA ADAPTER COUPLINGS

KP1529-1

FEMALE TO FEMALE 5/8" LH

CGA ADAPTER COUPLINGS

(COUPLINGS ONLY)

SHIELDING

GAS

COOLANT

OUT

NOTE:

ORDER K1859-1 ALONG WITH
K529-10 FOR WIRE FEEDERS
WITH QUICK DISCONNECT
FITTINGS.

COOLANT

COOLANT

GUN CABLE

IN
OUT

K529-10

COOLANT

COOLANT

ELECTRODE CABLE

TO WORK

CONTROL CABLE

COOLANT

IN

NOTE:

BLUE HOSE

RED HOSE

=

COOLANT

OUT

COOLANT

IN

=

COOLANT

IN

COOLANT

OUT

COOLANT

COOLANT

COOLANT

COOLANT

GUN CABLE

NOTE:

COOLANT

OUT

K1859-1 FOR WIRE

FEEDERS WITH QUICK

DISCONNECT FITTINGS

KP504 FOR HOOK-UP

TO WIRE FEEDERS

WITH CGA FITTINGS

COOLANT

IN

=

=

BLUE HOSE

RED HOSE

FIGURE 2

Water Cooled TIG Torch Connection

FIGURE 3

Water Cooled MIG Gun Connection

FIGURE 4

Connection to Wire Feeder (Do Not Use Water Solenoid)

FIGURE 5

Connection to Wire Feeder (Do Not Use Water Solenoid)