Low Profile – 1600 Advantage Series Service Manual – International

7

Fuse holder

Check, replace if necessary.

Gas pressure switch

Check for supply voltage to neutral

(internal to gas valve)

on both sides of switch. If voltage is

present on one side of switch only,

check the following. Check for proper

gas pressure supply to gas valve.(Marked

on oven spec. plate.) Check for proper

adjustment of gas pressure switch.

should be set at 10 Nat., 27 for L.P.

or 4.5 for town gas. Check gas filter in

gas valve for blockage or damage. (See

Adjustment section for location.)

If the above checks OK, but switch is

still not closed replace gas valve.

Oven air pressure switch

Check for supply voltage on both sides

of switch. If voltage is present on one

side only, check for air tube blockage.

Adjust air pressure switch. If the above

fails, replace air pressure switch.

Hi-limit thermostat

Terminals are normally closed. If open,

reset and test oven for proper operation.

If thermostat will not hold for maximum

oven temperature, and oven is not

exceeding maximum temperature dial

setting, check for proper location of

capillary bulb in its spring holder.

If above checks OK, replace hi-limit.

Ignition control

Check for supply voltage to ignition

control at terminal #1 and neutral.

If voltage is not present, trace wiring

back to hi-limit thermostat. Check for

supply voltage at terminal #6 to neutral.

If no voltage is present, wait 30 seconds

and check reset button. If above fails,

replace ignition control.

Burner reset switch

Switch is normally open. Check to see

that the switch closes when reset button

is pushed. Replace as needed.

Burner blower motor

Check for supply voltage to burner

blower motor.

WITH POWER OFF: Turn blower

wheel to check for locked rotor. If

supply voltage is present and motor does

not run, replace motor.

Burner blower motor

Check for supply voltage switching to

Air pressure switch

terminal N. O. as the air pressure switch

closes. Check for air tube blockage or

misalignment, adjust air pressure switch.

If the above fails, replace air pressure

switch.

Spark generator

After a pre-purge time of 30 to 60

seconds after blower motor starts,

check for supply voltage to spark

generator. If voltage is not present,

Check reset button located on rear of

control box. If voltage is still not

present, replace ignition control.

If voltage is present, visually check

for spark at igniter head.

Igniter/sensor assembly

Check for visible damage to igniter/

sensor assembly. If there is no visible

damage to the components, and no spark,