Lincoln Impinger Conveyor Ovens 1634-000-EA User Manual

Page 9

Advertising
background image

Low Profile – 1600 Advantage Series Service Manual – International

9

as needed.

Temperature regulation

If supply voltage is present on the

valve

temperature control board at the load

terminals #7 and #8, check for voltage

at temperature regulation valve. If

voltage is present, listen for valve to

open and close. Also, check for opens

or shorts in the coil. Replace if required.

Intermittent heating

Thermal overload of

The main fan motors and the burner

main fan and burner

blower motors are equipped with

blower motors

internal thermal protection and will

cease to operate if overheating occurs.

As the motors overheat and then cool,

this will cause the units to cycle on

and off intermittently. This may be

caused by improper ventilation or lack

of preventive maintenance. Also, most

of the problems listed under “Oven

will not heat” can cause intermittent

failure.

Conveyor will not run

Power supply

Check for supply voltage at terminals

L1 and L2. If voltage is not present,

check breakers.

Fan switch

See procedure for checking on page 6.

Fuse, 10 Amp.

Check and/or replace.

Fuse holder

Check and/or replace.

Filter E.M.I.

Check for supply voltage input to

filter. If there is no voltage, trace wiring

back to relay. If there is input voltage,

check for output voltage. If there is

input voltage but no output voltage,

replace filter.

Speed adjustment

This is a 0 to 10K ohm, 1 turn

potentiometer

potentiometer. With power off, remove

the black and white pot leads from the

conveyor control board at terminals

P1 and P2. Place the meter leads on

black lead (P2) and the white lead (P1).

Rotating the pot. slowly, from low to

high, the meter reading should show

an even transition from 0 to 10K ohms

±

5%. There should be no dead or open

spots through the one turn of the pot.

Check both leads to ground. There

should be no continuity to ground.

If any of the above fail, replace

the potentiometer.

D.C. motor

Check for supply voltage input to

control board

the control board at terminals L1 and L2

If not present, check wiring back to

the filter. If supply voltage is present,

check both fuses on the control board

( 8 Amp. line and 1Amp. armature).

Check the D.C. voltage output at

terminals A+ and A-. If A.C. voltage

is at terminals L1 and L2, and no

D.C. voltage is present at A+ and A-,

replace control board. If A.C. voltage is

present and D.C. voltage is present but

the motor will not run, check gear motor

as follows:

Conveyor

If D.C. voltage is present at A+ and A-