Service Manual 33

Troubleshooting Guide

Electronic Parts Troubleshooting Guide

The Product doesn’t operate at all.

Turn off the main power and wait until LED on outdoor PCB is off

Turn on the main power again.

Does the Operating LED of indoor unit blink

When Operation's ON?

Refer to the self-diagnosis function.

Is the Connection between CN-POWER of indoor

unit and terminal block?

Check the connecting state of connector

Is the Connection of cable between indoor and

Outdoor unit right?

Check the diagram wiring on the control panel

Is the voltage of CN-POWER in outdoor

PCB ASS'Y about AC220/240V?

Check the main power.

Check the Fuse of outdoor PCB Ass'y.

Check the connecting state of wires

Confirm Auto Addresssing work method

Check the Auto Addressing Work

Replace the PCB Ass'y

* The product's operation starts at three minutes after main power turning on

Trouble 1