When vertical louver does not operate trouble 5 – LG LCN240CP User Manual

Page 37

Advertising
background image

Service Manual 37

Troubleshooting Guide

• Confirm that the Vertical Louver is normally geared with the shaft of

Stepping Motor.

• If the regular torque is detected when rotating the Vertical Louver with

hands

Normal

• Check the connecting condition of CN-U/D Connector
• Check the soldering condition(on PWB) of CN-U/D Connector

If there are no problems after above checks

• Confirm the assembly conditions that are catching and interfering parts

in the rotation radial of the Vertical Louver

Check the operating circuit of the Vertical Louver

• Confirm that there is DC +12V between pin

(RED) of CN-U/D and

GND.

When Vertical Louver does not operate

Trouble 5