Lathem DDC2 User Manual

Page 35

Advertising
background image

Page 29

Digital Display Wall Clock Guide

DDC2 / 4-RS Wiring

Synchronous Wired

To
Other Clocks

115VAC

From

Master Clock

OPEN

1

2

3

4

5

6

7

8

Set switches 1-5 of S1 as shown.

Indicates depressed side of switch

Wiring applies to secondary wall clocks such as:

Cincinnati D8

Faraday

Honeywell ST402A

H

M

For 24VAC correction, use wiring
shown on page 23

B

L

U

/

W

H

T

Run

Correction

B

R

N

/

W

H

T

B

L

K

B

L

K

AC Return

Clock will correct minutes hourly at HH:58 and
hour and minutes twice daily beginning at 5:05.