background image

DDC2 / 4-RS Wiring

Digital Display Wall Clock Guide

Page 34

National Synchronous Wired

To
Other Clocks

115VAC

From

Master Clock

OPEN

1

2

3

4

5

6

7

8

Set switches 1-5 of S1 as shown.

Indicates depressed side of switch

H

M

For 24VAC correction, use wiring
shown on page 23

B

L

U

/

W

H

T

Run

Correction

B

R

N

/

W

H

T

B

L

K

B

L

K

AC Return

Clock will correct minutes hourly at HH:00 and
hour and minutes twice daily at 6:00.