Lux Products T10-1143SA User Manual

Page 3

Advertising
background image

3

TYPICAL SINGLE-STAGE

HEAT PUMP WIRING

Figure 12

110

G

Y

W RH

B

O

RC

COMP

FAN

24 VAC HEAT

TRANSFORMER

CHG.

OVER

ADD

JUMPER

BETWEEN

Y & W

ALT.

110

TYPICAL COOLING AND

HEATING SYSTEM

(5-WIRE)

FAN

COOL

COMP

GAS

VALVE

24 VAC HEAT

TRANSFORMER

110

Figure 11

24 VAC COOL

TRANSFORMER

REMOVE

JUMPER

BETWEEN

RH & RC

G

Y

W RH

RC

O

B

TYPICAL COOLING AND

HEATING SYSTEM

(4-WIRE)

Figure 10

110

GAS

VALVE

COOL

COMP

FAN

24 VAC HEAT

TRANSFORMER

G

Y

W RH

RC

O

B

TYPICAL HOOKUP FOR 3-WIRE

HEAT SYSTEM IF THIRD

WIRE IS FAN WIRE

Figure 9

GAS

VALVE

110

FAN

24 VAC

TRANSFORMER

G

Y

W RH

RC

O

B

TYPICAL HOOKUP FOR 2-WIRE

24V HEATING SYSTEM AND

MILLIVOLT SYSTEM

Figure 8

GAS

VALVE

110

24 VAC

TRANSFORMER

OR

THERMOPILE

G

Y

W RH

RC

O

B

These diagrams below are provided for new installations or unreferenced wires.

N O T E

If you have an electric system and the blower does not operate after installation, find the factory installed

yellow wire currently attached to the “Y” terminal and move it to the “A” terminal on the sub-base.