Theory of operation, Section e, Engine, excitation, rotor and stator – Lincoln Electric POWER-ARC 4000 SVM103-A User Manual

Page 38

Advertising
background image

ENGINE, EXCITATION, ROTOR
AND STATOR

A small DC voltage developed by the flywheel alterna-
tor in the Briggs & Stratton engine is fed to the rotat-
ing field coil in the rotor via a brush and slip ring con-
figuration. This excitation (“flashing”) voltage
magnetizes the rotor lamination. The rotor is mechan-
ically coupled to the engine. The rotating magnet
induces a voltage in the stationary windings of the
main alternator (stator).

Three separate and isolated windings are incorporated
in the stator lamination assembly. Each winding set
has a different number of turns, producing different
magnitudes of AC output voltages. The three windings
are the weld winding, the auxiliary power winding and
the field feedback winding. The field feedback wind-
ing provides rotor current during machine operation.
The output of the PowerArc 4000 is dependent on two
criteria: the engine RPM and the amount of current in
the rotor winding.

POWER-ARC 4000

THEORY OF OPERATION

E-1

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

ENGINE

STATOR

STATOR

ROTOR

REACTOR

BRIDGE

CAPACITOR

RHEOSTAT

115 AND 230VAC

RECEPTACLES

OUTPUT

TERMINALS

ROTATION

MECHANICAL

SLIP

RINGS

ROTOR

NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.

FIGURE E.2 – ENGINE, ROTOR AND STATOR