TROUBLESHOOTING & REPAIR

POWER-ARC 4000

F-14

ROTOR RESISTANCE TEST (continued)

FIGURE F.3 - BRUSHES RETAINED WITH CABLE TIE

CABLE

TIE

BRUSHES

9. Reinstall the brush holder assembly after

the test. Depress the spring-loaded
brushes into the holder and slip a suitable
non-metallic, fairly stiff retainer through
the slots at the top and bottom of the
holder. A cable tie works well; see Figure
F.3. This will hold the brushes up so that
you can easily install the holder.

10. Slip the holder into position in the gener-

ator end bracket. Be careful not to
loosen the 2 attached wires.

11. Reinstall and tighten the 2 screws with

the 1/4” nut driver.

12. Slowly remove the non-metallic retainer

from the brush holder and let the brush-
es snap back against the slip rings.

13. Snap the brush holder cover back into

position.

Advertising