TROUBLESHOOTING & REPAIR

POWER-ARC 4000

F-20

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

CH1

0 volts

5 ms

20 volts

This is the typical AC output voltage
generated from a properly operating
machine. Note that each vertical
division represents 20 volts and that
each horizontal division represents 5
milliseconds in time. The mahine
was loaded with a resistance grid
bank.

Note: Scope probes connected at
machine output terminals.

SCOPE SETTINGS

Volts/Div ....................20V/Div.
Horizontal Sweep ....5 ms/Div.
Coupling ............................DC
Trigger .........................Internal

MACHINE LOADED TO 125 AMPS AT 23 VAC

TYPICAL WELD OUTPUT WAVEFORM

MACHINE LOADED