NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

WARNINGS

Improper installation, adjustment, alteration,

service or maintenance can cause injury or

property damage. For assistance or additional

information, consult a qualified installer, service

agency or your gas supplier.

Operation of this appliance when not connected

to a properly installed and maintained venting

system can result in carbon monoxide (CO)

poisoning and possible death.

Carbon monoxide poisoning – early signs of

carbon monoxide poisoning resemble the flu

with headaches, dizziness, or nausea. If you

have these signs, get fresh air at once! Have

the heater inspected by a qualified service

technician. Some people are more affected by

carbon monoxide than others. These include

pregnant women, people with heart or lung

disease or anemia, those under the influence

of alcohol and those at high altitudes.

9. Push in control knob all the way and hold in. Immediately light

the pilot by triggering the piezo igniter (pushing the button)
until pilot lights. Continue to hold the control knob in for about
1­1/2 minutes after the pilot is lit. Release knob and it will pop
back out. Pilot should remain lit. If it goes out, repeat steps
5­9.

• If knob does not pop up when released, stop and immedi­

ately call your service technician or gas supplier.

• If the pilot will not stay lit after several tries, turn the gas

control knob to "OFF" and call your service technician or
gas supplier.

10. After pilot is lit, turn gas control knob counterclockwise

.2

to "ON." Knob can only be turned to "ON" if the knob

has popped out.

11. To turn burner on, turn "ON/OFF" rocker switch to "ON" or

set the thermostat to the desired temperature above room
temperature.

12. Adjust the flame height (and heat output) by turning the flame

height knob clockwise for full flame and counterclock­
wise for reduced flame.

13. Turn on the electric power to the appliance and set the blower

to the desired air flow after it turns on when the appliance
reaches operating temperature.

TO TURN OFF GAS TO APPLIANCE

1. Turn off the "ON/OFF" rocker switch and/or thermostat (if

installed) to its lowest setting.

2. Turn off electric power to the appliance if service is to be

performed.

3. Access the control compartment. Push in gas control knob

slightly and turn clockwise to "OFF." Do not force.

SHUTDOWN PROCEDURE

To turn off the burner, turn the rocker switch to "OFF" or adjust

the thermostat (if installed) to a setting below room temperature.

The pilot will remain lit for future burner ignition. For complete

shutdown, see "TO TURN OFF GAS TO APPLIANCE" above.

PILOT ASSEMBLY

Thermopile

Veilleuse à gaz Igniter (electrode)

Allumeur

Thermocouple

Gas Pilot Hood

Robertshaw Millivolt Gas Valve

TP/TH

TH

TP

Gas Control Knob

(Pilot / On / Off)

O

FF

O

N

Piezo Igniter

Allumeur

ON/OFF Switch

Interrupteur

Flame Height Control

Knob (HI/LO)

Figure 16

IMPORTANT NOTE: When opening the lower door on the face

while the insert is burning, pull at the far left or far right

vent openings, because the door is hot during operation.

Advertising