Specifications introduction – Langley/Empire RH-25-6 User Manual

Page 5

Advertising
background image

Page 5

12821-6-0406

Introduction

Always consult your local Building Department regarding regu-

lations, codes or ordinances which apply to the installation of a

vented room heater.
Instructions to Installer

1. Installer must leave instruction manual with owner after instal-

lation.

2. Installer must have owner fill out and mail warranty card sup-

plied with vented room heater.

3. Installer should show owner how to start and operate vented

room heater and thermostat.

Warning:

Any change to this vented room heater or its controls can

be dangerous. Any safety screen or guard removed for

servicing a vented room heater must be replaced prior to

operating the vented room heater.

General Information

This series is design certified in accordance with American National

Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian

Standards Association, as a Vented Room Heater and must be

installed according to these instructions.
Any alteration of the original design, installed other than as

shown in these instructions or use with a type of gas not shown

on the rating plate is the responsibility of the person and com-

pany making the change.
Important

All correspondence should refer to complete Model Number, Serial

Number and type of gas.
Notice: During initial firing of this unit, its paint will bake out and

smoke will occur. To prevent triggering of smoke alarms, ventilate

the room in which the unit is installed.

Installation on Rugs and Tile

If this appliance is to be installed directly on carpeting, tile, or other

combustible material, other than wood flooring, the appliance shall

be installed on a metal or wood panel extending the full width and

depth of the appliance.
The base referred to above does not mean the fire-proof base as

used on wood stoves. The protection is primarily for rugs that may

be extremely thick and light-color tile that can discolor.
Floor pad is available from Empire Comfort Systems, Inc., Part

Number DVP-1.
Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equip-

ment or accessories and repair and servicing of equipment shall

be performed only by a qualified agency. The term “qualified

agency” means any individual, firm, corporation, or company

which whether in person or through a representative is engaged

in and is responsible for (a) the installation or replacement of gas

piping or (b) the connection, installation, repair or servicing of

equipment, who is experienced in such work, familiar with all

precautions required and has complied with all the requirements

of the authority having jurisdiction.

State of Massachusetts: The installation must by made by

a licensed plumber or gas fitter in the Commonwealth of

Massachusetts.

The installation must conform to local codes or, in the absence

of local codes, with the National Fuel Gas Code, ANSI Z223.1

*/Canadian Installation Code, CAN/CGA B149.

*Available from the American National Standards Institute, Inc., 11 West 42nd St.,

New York, NY 10036.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), input ratings

should be reduced at the rate of 4 percent for each 1,000 feet (305m)

above sea level. Canadian High Altitudes for locations having

an elevation above mean sea level between 2,000 feet (610m) and

4,500 feet (1370m), the manifold pressure is to be decreased from

4.0" w.c. (.996kPa) to 3.2" w.c. (.797kPa) for Natural Gas and from

10.0" w.c. (2.49kPa) to 8.0" w.c. (1.99kPa) for Propane Gas.

Model

RH-25

RH-35

Input BTU.HR (KW/H)

25,000 (7.3)

35,000 (10.3)

Height

26" (660mm)

26" (660mm)

Width

37" (940mm)

37" (940mm)

Depth including diverter

18 3/8" (467mm)

18 3/8" (467mm)

Gas Inlet Pipe

1/2" (13mm)

1/2" (13mm)

Size of flue collar

4" (102mm)

4" (102mm)

Floor to top of collar on vertidcal position of Draft Diverter

22 15/16" (583mm)

22 15/16" (583mm)

Floor to center of collar on horizontal position of Draft Diverter

18 3/16" (462mm)

18 3/16" (462mm)

Accessories
Blower Package

DRB-1

DRB-1

Floor Pad

DVP-1

DVP-1

SPECIFICATIONS

INTRODUCTION