12821-6-0406

The correct flame will be almost horizontal, blue and will extend

past the thermocouple 1/4" (6mm). The flame will surround the

thermocouple just below the tip.
On Propane (LP-gas) slight yellow might occur where the pilot

flame and the burner flame meet.
Natural gas pilots require adjusting when the inlet pressure is above

5" w.c. (1.25kPa) Remove pilot adjustment cover. Turn adjust-

ment screw clockwise to reduce flame.
Propane (LP-gas) will not require adjusting.
After use, cleaning of the pilot burner may be required for the proper

flame. The pilot orifice can be cleaned with high pressure air or

by placing under running water. Pilot orifice must be dry before

replacement. Use a pipe cleaner to clean inside the pilot after the

pilot orifice has been removed.
To Remove Pilot Orifice

1. Disconnect the pilot supply line at the pilot burner.

2. Remove pilot orifice from pilot burner.It may be necessary to

tap on pilot burner in order to remove the pilot orifice.

Figure 5

There will be a short blue inner flame with a larger, lighter blue

secondary flame. The burner flame may have yellow tips when

hot. Dust in the combustion air will produce an orange or red

flame. Do not mistake the orange or red flame for an improper

yellow flame.
Attention: On Propane gas, if a whistling noise (resonation) occurs

close the air shutter on the main burner in order to reduce the amount

of primary air. The reduction in primary air will soften the main

burner flame and will eliminate the whistling noise (resonation).
On Propane or Natural gas if a yellow flame occurs open the air

shutter on the main burner in order to increase the amount of primary

air. The increase in primary air will sharpen the main burner and

will eliminate the yellow flame.

After use, cleaning of the main burner may be required for the proper

flame. The main burner may be cleaned by forcing water into the

ports and the throat of the burner. The burner should be blown dry

or heated to remove all water before replacement.

Figure 6

On Propane Gas, if a whistling noise (resonation) occurs

a. Close the air shutter on the main burner in order to reduce

the amount of primary air.