B. WALL MOUNTING

1) Remove the table-stand. To do this, pull down on the

stand from the rear and rotate forward.

2) Fix a screw (not included) into the desired wall,

leaving approximately 3/16 of an inch (5mm)
extended from the wall.

3) Place the Wireless Temperature Station onto the screw

using the hanging hole on the backside.

4) Gently pull the Wireless Temperature Station down to

lock the screw into place.


TROUBLESHOOTING
NOTE:
For problems not solved, please contact La Crosse Technology.

Problem:
No reception of WWVB time signal.
Solution: 1) Wait overnight for signal.

2) Be sure the Wireless Temperature Station is at least 6 feet from any

electrical devices, such as televisions, computers, or other radio-
controlled clocks.

3) Remove batteries for five minutes, reinsert and leave the unit alone

overnight without pressing buttons.

4) If there are still problems, contact La Crosse Technology


Problem: Hour is incorrect (minute and date are correct)
Solution: Be sure correct time zone and daylight saving time settings are selected.

Problem: The LCD is faint
Solution: 1) Set the LCD contrast to a higher number

2) Replace batteries


Problem: No outdoor temperature is displayed.
Solution: 1) Remove all batteries, reinsert into remote temperature sensor first, then

display.

2) Place remote sender closer to display.

3) Be sure all batteries are fresh.

4) Place remote temperature sensor and Wireless Temperature Station in

position so the straight-line signal is not passing through more than two
or three walls.